Fuse Data; Dc Power (Optional); Ground (Gnd) Or Earth; Proper Operations For Emissions (Ce) - Comtech EF Data SDM-2020 Installation And Operation Manual

Satellite demodulator
Table of Contents

Advertisement

Installation
2.3.7

Fuse Data

Fuse Type
Fuse
To replace a fuse, proceed as follows:
1. Remove the fuseholder on the back of the IEC 320 style A/C input connector
2. Replace fuse with same or equivalent rated part and/or model number.
Refer to Input Power requirements as specified in Chapter 1, 1-6.
2.3.8

DC Power (Optional)

DC power is an available option. Contact EFData Customer Support for further
assistance.
2.3.9

Ground (GND) or Earth

A #10-32 stud is available on the rear panel for the purpose of connecting a common
chassis ground among all of the equipment.
Note: A safety ground is provided through the AC power connector.
2.4

Proper Operations for Emissions (CE)

Note: To ensure compliance with the EMC Directive 89/336/EEC, properly shielded
cables for Data I/O shall be used. These cables shall be doubled-shielded from end-to-
end, ensuring a continuous ground shield.
2–12
Littlefuse 215002 5 x 20 mm
T2A H250V
Time Delay, 2A, High Breaking Capacity
Double Pole
(Approved to IEC 127, Sheet V and Underwriters Laboratories)
(Figure 2-3).
SDM-2020 Satellite Demodulator
Rev. 3