2.11
2.11
The MaxiProx Reader can be operated over the full range of 11.6-28.5VDC. Current requirements are
200-mA average and 700 mA peak at 12 VDC input. At 24 VDC (21 to 28.5 VDC) input the average
current is 260 mA and peak is 1.2 A. A linear regulated supply rated at 2.0 A is recommended. Noise
from devices such as switching power supplies, computer monitors, and arc welders can reduce the
read range or make the unit inoperable. Keep these devices at least 10 ft away from the Reader. With
the MaxiProx and power supply wired together, apply power to the Reader.
CAUTION!
The shunt jumper P2 is not installed as the factory default for +24VDC operation. If the jumper is in the
+12 VDC position and +21 to +28.5 VDC is applied, circuit damage can result.
2.12
2.12
The MaxiProx is tuned correctly when the autotune LED is
position the Reader at minimum of 4 inches away from metal in the mounting surface.
2.13
2.13
Apply Power to the Reader and the LED will display a sequence of flashes and beeps, indicating the
LED control mode. Two flashes of green and two beeps followed by a short delay, then one additional
flash (beep), is the correct sequence for "Green Flash/Beep on valid read" (SW1-5 off). Three initial
green flashes and beeps followed by a pause and then one additional beep indicate no Green
Flash/Beep on valid read (SW1-5 on).
2.14
2.14
Following this initial power up sequence the Reader will perform power-up Autotune. It will beep and
turn the access LED amber for ~1 second to indicate that a power-up tune test is about to begin. It will
then attempt to tune. If it successfully tunes, it will give two quick beeps and a
and tune LED's to indicate the Reader is tuned. If unsuccessful, the unit will give a single 1.5-second
beep with a
check for large areas of metal less than 4 inches from the back of the unit.
2.15
2.15
Periodic Autotune retunes every 1-minute.
2.16
2.16
During idle periods in normal operation, a periodic supervisor 1 byte transmission is sent to the host
controller over the Wiegand interface every 1 minute. Supervisor Mode is only available in Wiegand
Interface Mode.
2.17
2.17
Replace the top cover and top cover screw. Make sure that the autotune indicator LED remains in a
steady green state. If the LED is red, remove the cover and re-mount the unit using a non-metallic
spacer to position it further away from the mounting surface. Reinstall the cover, verify autotune, and
install the front label over the top cover screw and the autotune indicator lens.
HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA • Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690
http://www.hidcorp.com
Проектирование. Монтаж. Продажа. - http://vskd.ru

Power Supply

Power Supply

Autotune Operation

Autotune Operation

Reader Testing

Reader Testing
Power - - Up Tune
Power
Up Tune
red
on the access and tune LED's. If Autotune is not successful, the installer should

Periodic Autotune

Periodic Autotune

Supervisor Mode

Supervisor Mode

Install Cover

Install Cover
MaxiProx DFM Reader Installation Manual 5375-901 Rev D
green.
red
If the LED is
, use a spacer to
green
Page
on the access
10 of 20

Advertisement

Table of Contents
loading

Table of Contents