Maintenance - Blackridge BRG1700 User Manual

1700w inverter generator
Table of Contents

Advertisement

MAiNTeNANce iNFoRMATioN
If scheduled maintenance is NOT carried out then
this will void your warranty. Use the Service Log
on page 23 to keep track of the regular servicing.
Ensure that the authorised service agent has
dated, signed and stamped this log to ensure your
warranty is not void.
Fuel Tank Filter, pic. 18
The fuel tank filter should be checked every time
you fill up the fuel tank. If dirty, replace. Your
fuel tank filter should be replaced every 50 hours
(operation) or every 3 months, which ever occurs
first or whenever considered necessary.
To check or replace the fuel tank filter;
1. Remove the fuel tank cap.
2. Remove the fuel tank filter.
3. If dirty replace fuel tank filter before using the
generator.
4. Push new fuel tank filter into the top of the fuel
tank.
5. Replace the fuel tank cap.
Fuel line Filter
The fuel line filter should be replaced every 50
hours (operation) or every 3 months, which ever
occurs first or whenever considered necessary.
This must be replaced by an authorised service
agent.
This servicing must be carried out as noted above
or your warranty will be void.
Spark plug
Spark plug should be checked every 50 hours
(operation) or every 3 months and replaced
every 100 hours (operation) or every 6 months,
which ever occurs first or whenever considered
necessary.
1. Slide the plug panel off the generator, Pic. 19.
2. Unplug the spark plug lead off the spark plug;
Pic. 20.
3. To clean use a wire brush/nail file and remove
the carbon deposits on spark plug base
4. Check the spark plug gap using a feeler gauge.
The gap should be 0.6mm ≈ 0.7mm (0.024" ≈
0.028")
5. The replacement spark plug is Torch A7RC or
NGK CR7HSA
pic. 18
Fuel tank filter under
fuel tank cap
pic. 19
pic. 20
19
Slide plug
panel off
Lift the plug cap off
the spark plug
Lift the plug cap off
the spark plug

Advertisement

Table of Contents
loading

Table of Contents