Download Print this page

Beckett R7184 Technical Bulletin

New features in the beckett r7184 series 5 primary controls

Advertisement

TECHNICAL INFORMATION BULLETIN
NEW FEATURES IN THE BECKETT R7184 SERIES 5
Advances in electronics technology are making an exciting impact in our oilheat industry. These developments
have enabled control manufacturers to put high-performance features into residential primary controls.
Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added
features to meet the need of a changing industry. This technical bulletin will discuss some of the new
benefits and wiring improvements to the Beckett R7184 revision 5 primary control.
The operational sequence, interrupted
ignition, limited recycle and reset,
diagnostic LED and communication
port remain consistent on the R7184A,
B, P revision 5 as with the previous
revision.
How to tell the revision level:
The Revision numbers 1, 2 and 3
are located on the label designated
by the number printed on its side.
Revisions 4 and 5 have been
relocated to the side of the primary
control cover. The number also
is printed on its side.
Component color code
Igniter
Blue
Valve
Violet
Motor
Orange
Black
Line
Red
Limit
PRIMARY CONTROLS
BENEFITS
Matching wire colors between components and control will
reduce mistakes during wiring.
Quick Connects on the lead wires from the burner components
and wire harnesses allow quick component change-out and
reduce the number of leads in the wiring box.
Data port connection enables reading control characteristics
with Honeywell Diagnostick
QuickRead
EnviraC
future networking customization for HVAC systems.
Series 5 Control:
Alarm contacts
BECKETT R7184 PRIMARY CONTROL
Series 4
, QS7100T tester or OnWatch
711.
communication terminals have been added for
OM
New and relocated features
APRIL 2004
Series 5
Data port
EnviraC
OM
(3) terminals
or
T-T
(2) terminals

Advertisement

loading

Summary of Contents for Beckett R7184

  • Page 1 Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added features to meet the need of a changing industry. This technical bulletin will discuss some of the new benefits and wiring improvements to the Beckett R7184 revision 5 primary control.
  • Page 2: Wiring System Changes

    R.W. Beckett Corporation • P. O. Box 1289 • Elyria, Ohio 44036 • (800) 645-2876 • (440) 327-1060 • FAX (440) 327-1064 R.W. Beckett Canada Ltd. • Unit 3 - 430 Laird Road • Guelph, Ontario, Canada N1G 3X7 • (800) 665-6972 • FAX (519) 763-5656...

This manual is also suitable for:

R7184 series 5