A/D Reading Is Below 750 - Air Weigh LoadMaxx Installation Manual

Hide thumbs Also See for LoadMaxx:
Table of Contents

Advertisement

connect to the deflection sensor test box. Ensure the locking
tabs on the connector plug engage completely (Fig. 25).
Fig. 25: Assembling the Electrical Connector
2. Tighten both nuts and use a torque wrench to torque.
NOTE: When tightening the bolts, ALWAYS check the
torque on the nut, NOT the bolt head.
3. Verify the A/D reading using the display in the cab (start the
ignition to power on the display) or the deflection sensor test
box. If the reading is within range (750 to 1250), continue to
instructions for the final sensor torque. If the reading is not
within range, follow the instructions below.

A/D Reading is BELOW 750

If the A/D reading is below 750 or there is no A/D reading at all,
follow the steps below.
Loosen the nut on the non-cable end of the sensor.
Exert upward pressure lightly with your fingers (or a
screwdriver, if necessary) under the non-cable end of
the sensor until the A/D reading is between 750 and
1250.
Tighten the nut on the non-cable end of sensor and
torque. If the A/D readings are still within proper range,
continue to instructions for the final sensor torque.
27