Setting
Fan
This function provides the following options in the cooling
fans' operation when the projector is turned off (p.20).
L1 ...... Normal operation
L ...... Slower and lower-sound than the normal operation
(L1), but it takes more time to cool the projector down.
Lamp counter
This function is used to display the cumulative lamp
operating time and reset the lamp counter.
When the lamp life is left 0 hour, the Lamp replacement icon
(Fig.1) will appear on the screen, indicating that the end of
lamp life is reached.
When replacing the projection lamp, reset lamp counter.
See "Resetting the Lamp Counter" on page 65.
Note:
The Lamp replacement icon (Fig.1) will not appear when
the Display function is set to Off (p.46), during "Freeze"
(p.25) or "No show" (p.26).
Filter counter
This function is used to set a frequency for the filter replacement.
Use the Point ▲▼ buttons to select Filter counter and then
press the Point ► or the SELECT button to accese the
submenu items.
Filter counter......Show the total accumulated time of the
filter use timer setting.
Timer...................To set a timer, when the projector reaches
the time, the Filter replacement icon (Fig. 1)
appears on the screen and the total
accumulated time turns red, indicating
that the filter replacement is necessary. If
the filter is out of scroll and the projector
reaches a time set in the timer setting, Fig.
2 appears on the screen, indicating that the
filter cartridge replacement is necessary.
Filter counter reset..When replacing the Filter cartridge, reset the
Filter counter and the Scroll counter (p.62).
Scrolls remaining...When the filter scroll is counted down
to 1, Scroll counter on the screen is
showing "0 scroll(s)" , the last scroll
icon (Fig. 3) appears on the screen.
When the filter scroll is counted down
to 0, the Filter cartridge replacement
icon (Fig. 4) appears on the screen and
the WARNING FILTER indicator lights
orange, indicating that the filter cartridge
replacement is necessary.
Scroll counter Reset..When replacing the Filter cartridge, reset the
Filter counter and the Scroll counter (p.62).
Note:
• Do not reset the counter(s) when the filter or the filter
cartridge are not replaced.
• Timer setting notifies that the filter needs replacement. To
replace the filter, use the filter control function (p.53).
56
Fig .1 Lamp replacement icon
This icon appears on the screen when the end of
lamp life is reached.
Note:
At turning on, the icon (Fig.1) will appear.
Filter counter
Press the SELECT button to select Timer, and then use
the Point
buttons to set the timer. Select from (Off/
▲▼
400H/ 700H/ 1000H) depending on the use environment.
Fig.1 Filter replacement icon
Filter replacement icon appears on the
screen at a set time.
Fig.2
Fig.3 Last scroll icon
Last scroll icon appears on the screen
when the filter is down to the last scroll.
Fig.4 Filter cartridge replacement icon
Filter cartridge replacement icon appears
on the screen when the filter scroll is
counted down to 0 scroll.
Note:
• Fig.1, Fig.2, Fig.3 and Fig.4 appear at turning
on and selecting input source.
• Fig.1, Fig.2, Fig.3 and Fig.4 will not appear
when the Display function is set to "Off" (p.46),
during "Freeze" (p.25), or "No show" (p.26).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xc56 - 3100

Table of Contents