Factory Default Settings; Specifications - DENECKE JB-1 User Manual

Table of Contents

Advertisement

Cross Jam Mode Indications:
If the JB-1 is set to Jam Once (JO) mode, it can jam sync between any TC Input Rate and any Output Rate. When this occurs and
the rates are not the same, Cross Jamming is indicated by XJO. The Frame Rate Indication will indicate the User-selected TC
OUT Frame Rate.

Factory Default Settings

Mode
Frame Rate
Timecode Setup:
TC Output Level
UB Setup:
Rollover Setup
Backlight Timer

Specifications

TC Input:
TC Output:
TCXO Crystal:
Battery Power:
Battery Life:
External Power:
Size:
Weight:
Contents
Included with the JB-1 is a USB cable, and Quick Start Guide.
Custom cables are available. Contact Denecke Dealers for details.
©2018 Denecke, Inc.
Denecke JB-1 User's Manual
Auto Jam Once
23.976
0 dB
UB Field 3 (for American Date Standard MM-DD-YY-00, to rollover days)
30 seconds
-15dB (0.5V to 5V) @ 4.7K; BNC Connector
Selectable from 0 dB (2.0V), -6 dB (1.0V), -12 dB (0.50V), -22 dB (0.16V), -26dB (0.10V), -46 dB
(0.01V), and two user programable levels between 0.00V to 2.40V; BNC Connector
+/- 0.1PPM @ -40º to +85º C (less than a half frame drift per day)
Internal LiPo cell
Approx. 150 Hours (12 Hours with Back Light Continuously ON)
5V, via Micro USB Connector
1.84" (W) x 1.36" (H) x 0.63" (D) (46.7mm x 34.5mm x 15.9mm)
2 oz.
25209 Avenue Tibbitts * Valencia, CA 91355 * (661)607-0206