Sanyo MPX-CD162 Instruction Manual page 41

Sanyo fisher co. instruction manual multiplexer mpx-cd162, mpx-md162
Table of Contents

Advertisement

CAMERA SETTING
Setting the sequential display interval for each
camera
1
Press the MENU button twice to display the (TIMER
SET) menu, then check that the day and night periods
are set as desired. (For more information on the day
and night periods settings, see "TIMER SET" on page
27.)
2
Press the MENU button four times to display the
(MONITOR SET) menu.
3
1 Using the + (or –) button, set "INDIV." for the "MON1
SEQ.TIMER" item, then press the l button.
2 Using the + (or –) button, set "INDIV." for the "MON2
SEQ.TIMER" item.
4
Press the MENU button once to display the (CAMERA
SET) menu.
5
Press the SELECT (1 – 16) button to select the desired
camera (ex: camera 5).
6
Press the l button to highlight the "SEQUENCE"
setting.
1 Press the + (or –) button to set the desired sequential
display interval (ex: 10 sec.) in the DAY column, then
press the c button.
2 Press the + (or –) button to set the desired sequential
display interval (ex: 20 sec.) in the NIGHT column.
7
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
CAMERA SET menu
SEQUENCE
(Default setting: DAY and NIGHT to 1 S)
If in the (MONITOR SET) menu, the items "MON1 SEQ.TIMER"
and/or "MON2 SEQ.TIMER" are set to "INDIV.", enter the
desired sequential display interval for each camera.
The available durations are: 1 to 30 sec., SKIP
SKIP: In automatic sequential display, this camera will not be
displayed.