Digital Thermometer
User's Manual
OFFSE T
SETUP
T1 T2
T1-T2
TYPE KJTERSN
USB
INTERV AL hour:min
:
T1 T2
CAL
min:sec
POWER
HOLD
MAX
AVG
MIN
SETUP
THERMOMETER
TC2100
READ
REC
HOLD
K
°F
°C
mV
K
MAX
MIN
AVG
MEN
°F
°C

Advertisement

Table of Contents
loading

Summary of Contents for Perfect Prime TC2100

  • Page 1 TC2100 Digital Thermometer User’s Manual OFFSE T SETUP READ HOLD T1 T2 T1-T2 °F °C TYPE KJTERSN INTERV AL hour:min T1 T2 °F °C min:sec POWER HOLD SETUP THERMOMETER...
  • Page 2: Table Of Contents

    CONTENTS CONTENTS 5.4 Viewing MAX, 1. Safety Information........MIN and AVG Readings......12 2. Product Overview........5.5 Use Offset value To Adjust 3 .Recognize Meter.......... Temperature probe error......13 3.1 Component............4 5.6 User Self-Calibration........13 3.2 Display...............5 6. Data Storage..........15 3.3 Keys Description..........
  • Page 3: Safety Information

    1.Safety Information 7. Insulated thermocouple should be used. In order to use the thermometer safely and correctly, please read this manual carefully first, especially the 8. Thermometer should be repaired only using manufacturers “Safety Information” part. It is recommended to keep replacement parts.
  • Page 4: Product Overview

    Electrical Symbols 3. Meter Description 3.1 Components Note-important safety information, refer to the instruction manual. Conforms to UL STD. 61010-1, Certified to CSA STD C22.2 NO. 61010-1 Complies with European (EU) safety standards OFFSE T SETUP RE AD HOLD 2. Product Overview T1 T2 °F T1-T2...
  • Page 5: Display

    3.2 Display Auxiliary display USB port 1 2 3 Time display Indicate time display min: sec OFFSET SETUP READ HOLD Indicate calibrating state T1 T2 °F T1-T2 Indicate auto-save time setting °C Indicate time display hour: min TYPE KJTERSN USB MAX MIN AVG Indicate thermocouple probe type INTERVAL hour:min...
  • Page 6: Setting Meter

    4. Setting Meter MAX/MIN View maximum, minimum and average value. Press and hold to close /AVG 4.1 SETUP Option 1. Press the SETUP key to enter setup mode. HOLD Data hold To confirm, see user setting for details -->“ ” symbol will flash on the screen. ENTER SETUP To set, see user setting for details...
  • Page 7: Setup Option Setting

    4.2 SETUP Option Setting D. OFFSET(T2) setting: Users can adjust the thermometer to show value tahts A. Data storage interval setting (INTERVAL): compensated for the thermocouple probe error. See 1. Press the SETUP key to enter the data storage “Adjust the interval setting mode.
  • Page 8: Using The Meter

    5. Using The Meter 3. Press ENTER to select time format (hr:min/min:sec) 4. The system time is the current running time if not changed. 5.1 Connecting Thermocouple probe G. Power frequency setting (LinE): 1. Insert the thermocouple probe to input jack. To get the best result, please set the meter's power 2.
  • Page 9: Use Offset Value To Adjust Temperature Probe Error

    e) Press “ENTER” to save current calibration value. 5.5 Use offset Value To Adjust f) Press “T1/T2/T1-T2” / “TC TYPE” key to switch to Temperature Probe Error T1 measurement channel. Use OFFSET (T1) & OFFSET (T2) in the SETUP to adjust g) Input 0μV in T1 measurement channel.
  • Page 11: Data Storage

    6. Data Storage 6.3 Clearing Stored Data 6.1Data Storage Please refer to Data clearing (CLr) in 4.2 SETUP Manual storage is in the normal measurement mode Option Setting. and data storage interval (INTERVAL) is set to 00:00. 1. Press the “MEM” key to store an item of Data Transmission data.
  • Page 12 -->“ READ ” symbol will flash on the screen. To avoid damage, do not immerse the thermometer in 1. Press to read the next/previous data. water. -->“ MEM ” and number will shown on auxiliary display. 2. If there is no available storage space, “NULL” will be displayed for 2s.
  • Page 13 9.Technical Data <-10°C: within +0.5°C; <-200°C: The indicator is accurate within the temp. range within +1°C (18°C-28°C) and relative humidity is <80%. Warranty T-type < -200°C for reference only period is one year (thermocouple probe error not Time Relative time included).
  • Page 14 R-00-05-2312...