AXIS Q6054 Mk III PTZ Network Camera
Specifications
DC power input
Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in amplifier. A stereo connector must be used for the audio out.
I/O terminal connector - Use with external devices in combination with, for example, tampering alarms, motion detection, event
triggering, and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the
interface to:
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface or from the product's webpage.
Digital input — For connecting external devices that can toggle between an open and closed circuit, for example
PIR detectors, door/window contacts, and glass break detectors.
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.. If used with an
inductive load, e.g. a relay, a diode must be connected
in parallel with the load, for protection against voltage
transients.
AC power input
23
Specifications
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA