Promega GloMax-Multi Detection System Quick Start Manual

With instinct software

Advertisement

Quick Links

1.
Unpacking the
instrument
1.
2.
3.
2.
What's in
A.
the box?
3.
1.
2.
Setting
up the
instrument
3.
4.
Starting up
the instrument
©2011 Promega Corporation. All Rights Reserved. Printed in USA 12/11. 18284-PM-CR. Part# FB117
-Multi + Detection
GloMax
®
System with Instinct
Setting Up Your Instrument. It's Easy!
For the complete protocol see Technical Manual, TM340, on the CD provided with your instrument or go to:
www.promega.com/protocols and search for TM340.
CAUTION! The GloMax
®
two people.
5295MA.eps
Set the shipping box on a table, and remove the accessories and literature.
Carefully remove the GloMax
®
dust-free location with good air circulation. Leave at least 7.5 inches (19cm) of clearance in front of the instrument to
allow the instrument door to open without hindrance.
Install the Instinct Software™ on a PC/Windows
B.
C.
Open the accessories box included with your shipment,
and locate the instrument power cable.
Connect the AC Power Adapter to the power inlet on the
back of the Instrument. Connect the power cord to the
AC Power Adapter.
Plug the power cord into a grounded outlet.
Remove
Software
-Multi + Detection System weighs approximately 35lb (16kg) and should be handled by
-Multi + Detection System from the box and place on a flat, level, solid surface in a
computer.
®
The GloMax
Software Accessories:
A. Power Cord. B. AC Power Adapter. C. Microplate Adapter,
located inside the instrument. D. Two Optical Well Crosstalk Masks,
one for 96-well plates and one for 384-well plates. The 96-well Optical
Crosstalk Mask will be located inside the instrument. E. USB Flash
Drive (appearance may vary from Figure E).
Included but not shown: CD containing GloMax
E.
System Technical Manual (TM340) and Instinct software, one
spare red Breakaway Tab for the plate mechanism and a small
screwdriver.
Check to make sure all accessories are included with
D.
the instrument and are undamaged.
-Multi + Detection System. The power switch is located
1.
Turn On the GloMax
®
on the back panel next to the power connection. An orange LED located left
of the touch screen will illuminate.
2.
The instrument will initialize and calibrate for about one minute, at which point
the touch screen will activate and the Home screen will appear.
3.
In order to prevent damage to the instrument and loss of sample it is important
to have the Microplate Adapter in the correct orientation. Please refer to
Technical Manual TM340 for complete instructions.
Important: When using the instrument for the first time, you must press the
"Door" button and remove the red labels attaching the Microplate Adapter to the
Microplate Sample Tray.
Please refer to Technical Manual TM340 for detailed instructions on your
specific application.
5295MA.eps
-Multi + Detection System with Instinct
®
RS-232
USB
Injector system
Power
serial port
port
connection
inlet
Continued on other side.
-Multi + Detection
®
On/Off
switch

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GloMax-Multi Detection System and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Promega GloMax-Multi Detection System

  • Page 1 “Door” button and remove the red labels attaching the Microplate Adapter to the Microplate Sample Tray. Please refer to Technical Manual TM340 for detailed instructions on your specific application. Continued on other side. 5295MA.eps ©2011 Promega Corporation. All Rights Reserved. Printed in USA 12/11. 18284-PM-CR. Part# FB117...
  • Page 2 • Removing and Installing the Microplate Sample • Luminometer Operation Tray Cover • Visible Absorbance Photometer Operation • Troubleshooting • UV-Vis Absorbance Photometer Operation, Section 12 • Fluorometer Operation, Section 13 ©2011 Promega Corporation. All Rights Reserved. Printed in USA 12/11. 18284-PM-CR. Part# FB117...

Table of Contents