Lubrication Information - Oerlikon S16A2 Service Manual

Planetary final drive
Table of Contents

Advertisement

General Properties:
Differential Planetary
Ambient
Temperature
(1)
-40° to -5° F
-5° to 40° F
40° to105° F
(2)
105° to 150° F
Footnotes
1.
For operation in this ambient temperature range, synthetic oil is recommended with a pour point of
10°F lower than the minimum ambient temperature.
2.
For operation in this ambient temperature range, synthetic oil is recommended for proper lubricant
life at elevated temperatures.
Continued on Next Page
Planetary Final Drive Service Manual

Lubrication Information

The lubricant used in most Torque-Hub
based gear fluid containing anti-oxidation, anti-foaming and extreme
pressure additives. The lubricant should have a minimum viscosity
index of 95cst and maintain a minimum viscosity of 40cst under
normal operating conditions. Some applications require special
considerations; consult the machine manufacturer and Oerlikon
Fairfield for more additional information.
The table below lists the recommended viscosities for various
ambient operating temperatures. These recommendations are
based on temperature rise of 50° to 100°F at normal operating
conditions.
ISO Index
Lubricate
Number
VG100
VG150
VG220/VG320
5EP/6EP
VG460
Simple Planetary
AGMA
ISO Index
3EP
VG100
4EP
VG100
VG150/VG220
7EP
VG320
®
drives should be petroleum
AGMA
Lubricate
Number
3EP
3EP
4EP/5EP
6EP
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Torque-hub s16a1S12 series

Table of Contents