Sealing - Viega Advantix Top 4914.20 Instructions For Use Manual

Bath drain
Table of Contents

Advertisement

Mounting on a floor
Fig. 3: General mounting example – Mounting
on the floor
2.4.2

Sealing

Bonded sealing
Advantix Top bath drain
During the mounting on the floor, the drain is integrated into the floor
construction. At the same time, it can e. g. be integrated into the level-
ling screed or heat insulation. If necessary, a vertical drainpipe can be
led through a drill hole in the floor at the same time.
NOTICE!
The creation of a floor recess must be agreed with the fol-
lowing people:
– a structural engineer
– the on-site fire protection inspector or the specialist
engineer for fire protection
If necessary, proof of compliance with building code or an
expert's report must exist.
To protect against moisture penetration, apply sealing foils, which are to
be processed in liquid state, directly below the tiles on screed and
walls. The determination of the stress class and the underground as well
as the selection of the suitable bonded sealing must be carried out in
compliance with the valid standards and regulations, see:
tions from section: Sealing" on page 6 .
The bonded seal can be applied directly onto the drain flange.
Product information
Ä „Regula-
9 from 24