Viega Advantix Top 4914.20 Instructions For Use Manual page 10

Bath drain
Table of Contents

Advertisement

Important note
Advantix Top bath drain
Fig. 4: Diagram of a bonded seal
Careful planning is required for professional sealing. In addition,
depending on the individual dampness wear class and the type of foun-
dation, a suitable BS system with a building regulations certificate of
suitability must be chosen.
Furthermore, the following factors should be taken into account:
Drain or shower channel must be equipped with a special flange,
n
which has an adhesive surface and a width of at least 30 mm.
n
For bridging the material change from drain to screed, either a suit-
able sealing collar or sealing tape designed for overlapping with the
BS over a width of at least 50 mm must be used.
The screed must be laid at a minimum incline of 1–2 %.
n
n
The installation must be carried out properly in acc. with the
mounting instructions and the manufacturer's information.
1
2
9
Fig. 5: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 - Grate
2 - Top piece with adhesive flange
3 - Tile
4 - Tile cement
5 - Bonded sealing
6 - Screed
3
8
7
Product information
4
5
6
10 from 24