Installation height 85–95 mm
Advantix Top bath drain
Align the floor in such a way that the arrows point towards the drain
pipe.
Secure floor with clamping ring.
Tighten the screw of the clamping ring with max. 2.5 Nm ±0.2 Nm.
Alternatively, tighten the end of the clamping ring up to or between
the markings.
ð The water seal level is 40 mm and the immersion pipe length
38 mm.
Loosen clamping ring with screwdriver.
Handling
15 from 24