Download Print this page

ATEQ 6th series User Manual page 4

Electric connectors

Advertisement

3.3.5. Input and output Ethernet/IP
3.4. A
NALOG OUTPUTS
This option is not possible if Devicenet or Profinet options are installed.
Connection for analog outputs.
2
1
5
4
3
4. OTHERS CONNECTORS
The following connectors are located under
the gland cap:
4.1. C
ONNECTOR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pin 1
COMMUN (Outputs 1, 2, 3) + 24 V DC
Pin 2
Pin 3
Pin 4
Pin 5
COMMON (Outputs 4, 5, 6) + 24 V DC
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
Pin 15
Pin 16
* Inputs NPN or PNP following the strap position on the board.
Version 1.04a
Standard connection Ethernet TCP / IP protocol.
(
)
OPTION
Pin 1: sensor 1 (plus).
Pin 2: sensor 1 (minus).
C
6 O
/ 6
ODES
UTPUT
Output n°1, open collector
Output n°2, open collector
Output n°3, open collector
Output n°4, open collector
Output n°5, open collector
Output n°6, open collector
Input 0 (NPN or PNP)*
Input 1 (NPN or PNP)*
Input 2 (NPN or PNP)*
Input 3 (NPN or PNP)*
Input 4 (NPN or PNP)*
Ground
Input 5 (NPN or PNP)*
Ground
Sheet # 692/1u – Electric connectors (F610)
(
)
INPUTS
OPTION
Output / inputs codes.
Output
codes
24V DC
100mA Max
Inputs
Analogue
outputs
Pin 3: sensor 2 (plus).
Pin 4: sensor 2 (minus).
Charge / Load
1
24 V DC
2
3
4
5
6
7
8
User guide ATEQ 6th series Page 4/7
0,1 A max
Obligatory
diode for an
inductive load.

Advertisement

loading

This manual is also suitable for:

F610