Product Introduction; Technical Specifications - BEA Superscan Instruction Manual

Infrared presence beam
Hide thumbs Also See for Superscan:
Table of Contents

Advertisement

SUPERSCAN ACTIVE INFRARED PRESENCE BEAM
The SuperScan safety detector is a presence detection system that is primarily utilized on automatic pedestrian
swing doors. B.E.A., Inc. has found ways that the SuperScan can be utilized on industrial doors.
The electronic components come housed in a narrow aluminum extrusion that measures 34.5" and can be altered
to accommodate different door widths. The system comes complete for mounting to the door and includes a door
loop, which encases the wiring from the door to the door jamb.
Detection zones can be varied in range by a potentiometer adjustment, and in width by adding or taking away slave
modules from the master. These slave modules are simply added by inserting them into the aluminum extrusion
then connecting them with the attached flat ribbon cable to the next module. This can be done without interrupting
other modules in the same extrusion. Once installed, the zone (in addition to being adjustable for distance) can be
angled independently from the other modules. This means that the zone can be directed closer or farther away from
the face of the door.
Each SuperScan module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently
of the other modules. The transmitter emits an extremely precise beam, which measures approximately 4" in
diameter at a distance of 8'. The receiver in turn receives the infrared beam reflected off of the floor or other
reflecting surface. This transmission and reception forms a detection angle, which is the basic premise of detection
(called triangulation). Should this angle be interrupted, detection will occur. Detection is NOT based upon the
intensity of the beam, and in principle will not be affected by the color of the object that interrupts the angle.
Background color will not alter the performance of detection.
PLEASE NOTE: The SuperScan is water-resistant but not water-proof. Direct water spray is not
recommended. Any units sent back to B.E.A. with water damage would be 100% out of warranty.

TECHNICAL SPECIFICATIONS

Power Supply
Current Consumption:
Input Inhibit
Input Monitoring
Output Interface; relay
Detection Range
Distance Adjustment
Detection Time
Detection Signal Duration
Output Hold Time
LED Indications
Operating Temperature Range
PCB Dimensions
Connection to Door Controller
Connection: Master to Slave
Max. Number of Slaves
Functions Selection
75.1035 V1 Feb 2001
Output Relay: 12-24 V AC/DC ± 10%
Master: On = 60 mA max.
Master: Off = 30 mA max.
Slave: On = 40 mA max.
Slave: Off = 30 mA max.
12-24 V AC/DC ± 10%: Active when voltage is applied
12-18 V DC: Active when voltage is removed
Relay; max. contact rating is 1A @ 30V ( resistive)
0' to 8'2" (2.5 m)
2 ft. up to 8 ft. (.61m up to 2.44m) rotating cam with linear
adjustment
< 50 ms
Infinite Presence Detection
Potentiometer Range: 0.1 sec. to 4.5 secs.
Master: Red LED = Detection
Green LED = Active Output
Slave: Red LED = Detection
-30° F to 140° F
Master: 10.91" x 1.5" (277mm x 38mm)
Slave: 8.75" x 1.5" (222mm x 38mm)
8 Position Screw Terminal on Master PCB
Flat Ribbon Cable With Connectors and Key Lock
Standard = 9 / With Monitoring = 8 max.
Detection Mode - NO or NC
Standard Mode or With Protection Against Masking