Operation Of Button (Table 2); Troubleshooting; Technical Specifications; Conformity - 4-noks PR-SA Installation And Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

EN
5.

Operation of button (table 2)

Function
Command
Boost
Press briefly
Press and
Change of
hold (10
operating
seconds)
mode
during
power-up
6.

Troubleshooting

1) At power-up, an acoustic warning is heard, consisting of 3 beeps:
Switch off the device and turn the direction of the CT through 180 degrees
9
2) The Power Reducer SA does not divert power to the connected heating element
Verify correct operation of the heating element and of the relative electromechanical thermostat
9
Check the position of the current transformer (CT), which must be located at a point on the phase leaving the grid meter, upstream
9
of branches made within the electrical system.
7.

Technical specifications

General specifications
Power supply
Output
Status display
Protection
Connections
Current measurement
Ambient parameters
Degree of protection

Conformity

Dimensions (L x H x D)
8.
Conformity
All models comply with Directives 2014/30/UE(EMC), 2014/35/UE (LVD) e 2014/53/UE (RED). The appliance (or product) is subject to sorted
collection, in compliance with local regulations on waste disposal currently in force. The Astrel Group hereby declares that this product is
in compliance with essential requirements and other pertinent provisions established under Directive 2014/53/UE (RED). The declaration of
conformity can be viewed at www.astrelgroup.com.
9.

Safety and disposal

Electrical and electronic equipment requiring sorted collection, in compliance with local regulations on waste disposal currently in force.
Astrel Group reserves the right to change product specifications without notice.
Meaning
Activation of Boost function. In this condition, the connected heating element is activated at 100%
load, irrespective of the grid power available.
Power Reducer starts up in a different operating mode:
with Elios4you (1 beep on starting up)
stand-alone (2 beeps on starting up)
App-controlled power reducer for single-phase resistive loads (typically an electric water heater)
230 Vac (± 10%) 50 Hz
Output 3.0kW max, resistive
2 x visual alarm, system power on, system with Boost activated.
1 x Led with brightness proportionate to power reduction
Internal fuse rated 20 A (FF632320)
Screw terminals for power supply
Screw terminals for power supply to resistive load
Screw terminals for CT provided; cable L = 3000 mm
With split core CT (internal Ø 15 mm max)
Operating conditions: 5°C to +40°C; <80% R.H., non-condensing
Storage conditions: -20 to +70°C; <80% R.H., non-condensing
IP20
Directives 2014/30 EU; 2014/35 EU; 99/5 EEC; 2011/65 EU; EMC (Electromagnetic Compatibility);
EN 55014-1; EN55014-2; EN61000-3-2; EN61000-3-3; EN61000-6-2; EN61000-6-3; EN60335-1;
EN60335-2-21
280 x 405 x 70.5 mm