FREqUENCY
Function
400.0 mVac
4.000 Vac
4.000, 40.00 Vac
400.0 Vac
600 Vac
400.0 Aac
Display counts:
Resolution:
Overload Protection :
Transient protection :
CAPACItANCE
1)
Range
500.0nF, 5.000μF,
50.00μF, 500.0μF,
3000μF
1)
Additional 50.00nF range accuracy is not specified
2)
Accuracies with film capacitor or better
3)
Specified with battery voltage above 2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at low battery warning voltage of
approximately 2.4V
Transient protection :
Sensitivity
(Sine RMS)
350mV
1V
32V
90V
500V
60A
Range
10 Hz ~ 2 kHz
5 Hz ~ 5 kHz
5 Hz ~ 100 kHz
5 Hz ~ 10 kHz
5 Hz ~ 5 kHz
40 Hz ~ 400 Hz
5000
0.001Hz
ACA Clamp-on jaws : AC 600A rms
continuous
VAC input jacks : 6.5kV (1.2/50μs surge)
2) 3)
Accuracy
±( 3.5% + 6 digits)
6.5 kV (1.2/50 μs surge)
13
Accuracy
±( 0.5%+4 digits)
±( 0.5%+4 digits)
±( 0.5%+4 digits)
±( 0.5%+4 digits)
±( 0.5%+4 digits)
±( 0.5%+4 digits)