Page 50
Selects the function of the I/O board digital input. A contact closure between the two positions will activate the digital input. A dry contact or open-collector output can be used. The I/O Board option is required for the digital input.
Page 71
Function 1.E should be placed in "nOrL" mode. THEORY OF OPERATION: When a box passes photoeye 1 (TB1 POS. 3&4 toggles) the 8600 will display real time weight, and begin to recorded samples of stable weights, that are out of the 0 band.