Safety information:
WARNING – Do not change the battery in an flammable atmosphere.
WARNING – Substitution of components may impair intrinsic safety.
WARNING – Read the instruction manual before use.
Instructions specific for use in hazardous areas
The following instructions apply to equipment cov-
ered by certificate number:
Sira 03ATEX2102
The following information covers all relevant points
listed in clause 1.0.6 of the EHSR's of the ATEX direc-
tive.
UNITED KINGDOM OX14 4SD
. The certification marking is as follows:
1
The equipment is Category 2G and may be used in
2.
zones 1 and 2 with flammable gases and vapours
with apparatus groups IIA, IIB & IIC and with tem-
perature classes Tl, T2, T3 and T4
The equipment is only certified for use in ambient
3.
temperatures in the range -20°C to +50°C and
should not be used outside this range
Use only battery pack supplied by Crowcon.
4.
Charging is only permitted in the non-hazardous
area. DO NOT CHARGE IN HAZARDOUS AREA.
. The equipment has not been assessed as a safety-
5
related device (as referred to by Directive 94/9/EC
Annex II, clause 1.5)
6.
Repair of this equipment shall be carried out by
the manufacturer or in accordance with the appli-
cable code of practice.
Use only the appropriate Crowcon supplied cables
7.
for connection to the sockets at the rear of the
instrument.
If the equipment is used in a manner other than
8.
that specified in this manual, the protection pro-
vided by this equipment may be impaired.
Area Classifications: -
Zone 1: An area classified as Zone 1 is likely to have
ignitable concentrations of flammable gases,
vapours or liquids present under normal oper-
ating conditions.
Zone 2: An area classified as Zone 2 is not likely to
have ignitable concentrations of flammable
gases, vapours or liquids present under nor-
mal operating conditions.
© Copyright Crowcon Detection Instruments Ltd 2015.
All rights are reserved. No part of the document may be
photocopied, reproduced, or translated to another language
without the prior written consent of Crowcon Detection
Instruments Ltd.
Publication number: M07664
Sixth edition: January 2015