Setting Table Tilt Scale To 0; Leveling Extension Table - Grizzly Extreme Series Owner's Manual

14 inch extreme series bandsaw
Hide thumbs Also See for Extreme Series:
Table of Contents

Advertisement

Figure 28. Squaring table to blade.
6.
Secure plastic knobs and lock positive stop
bolt by tightening hex nut against casting.
Ensure bolt does not turn by holding with
another wrench while tightening hex nut.
Setting Table Tilt
Scale to 0˚
The pointer on the table tilt scale must be calibrat-
ed in order for the scale reading to be accurate.
To calibrate pointer on table tilt scale:
1.
Make sure blade is tensioned and is tracking
correctly, and that table is 90˚ to blade (this
procedure should be already completed with
Adjusting Positive Stop instructions).
2.
Loosen screw on pointer so pointer is able to
move.
3.
Align tip of pointer with the 0˚ mark on table
tilt scale.
4.
Tighten screw on the pointer so pointer is
locked in place.
G0555X (Mfd. Since 9/17)
Leveling Extension
Table
The extension table must be level with the main
table. It is important to keep the extension table at
least
" away from the main table during leveling
1
8
to allow the table room for tilting.
To level extension table:
1.
Set table to 90°.
2.
Locate lever board set screws underneath
extension table (see Figure 11 on Page 18)
and loosen hex nuts on set screws. This will
allow you to adjust set screws when leveling
extension table.
3.
Place a straightedge across the front of the
main table and extension table as shown in
Figure 29.
Figure 29. Leveling extension table with
straightedge.
-27-

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0555x