The Ica5Atex Connections; Ileatex Enclosure - Mantracourt ALA5 User Manual

2-wire 4-20ma atex load cell amplifier
Table of Contents

Advertisement

The ICA5ATEX amplifier is designed to fit into a pocket in a certified loadcell. Use the 2.1mm hole to secure the unit
and to provide a good ground connection.
The mounting hole will accept an M2 screw or American equivalent #0-80.
Important Note: DO NOT USE #2 screw size.
Take care when soldering cables to the pads. Use a temperature controlled soldering iron set to a maximum 330 ºC,
for no longer than 2 seconds per pad. Excessive heat or increased soldering time may result in damage to the PCB.
See fig 2.1 for recommended screen connections.

The ICA5ATEX Connections

The power supply should be between 9 and 28V and must be connected through an ATEX approved barrier if
installing into a hazardous area.

ILEATEX Enclosure

Package Contents
EMC 'O' ring
enclosure body
enclosure Cover
2 x EMC cable glands PG7/20 TPI 14mm AF
2 x grub screws
1 x M2 spring washer
1 x M2 cylindrical spacer
M2 x 12mm cap screw
Please refer to Appendix A – 'Special conditions of safe use'
Mantracourt Electronics Limited ALA5, ILEAtex and ICA5Atex User Manual
:
Body
Ensure that the 'O' ring is fitted to the body.
Cover
8