Download Print this page

GE Lumination RC Series Installation Manual page 6

Led luminaire, new construction frame

Advertisement

LRX-Series Mounting
AC line
18
Connect conduit end with input leads to existing
junction box and make proper connections. Connect
the black, white, and green/yellow wires of the input
leads to the black, white and green wires using twist-
on wire connectors and close junction box.
Optional dimmer: When connecting with dimming
controller, wires must be run through another
separate knockout hole. Connect the violet (dimming
+) and gray (dimming -) wires to the violet and gray
wires of the fixture.
NOTE: Please cover dimming leads with wire nuts if
you won't connect with dimming leads.
Dimming compatibility for both 0-10V and phase cut,
please refer to GE website:
www.gelighting.com/dimming.
Lumens Setting Switch
NOTE: For 1000/650lm and 4000/3000lm, default output lumen is 1000lm and 4000lm respectively. Push switch up or
left to activate 650lm and 3000lm respectively.
Wiring Diagram
L
N
Dimming +
Dimming –
Ground
0-10 Volt Dimming
Gray
LED
Driver
Violet
6
Black
White
LRX
Violet
Fixture
Gray
Green/Yellow
To 0-10V
0-10V –
Dimmer
0-10V +

Advertisement

loading

This manual is also suitable for:

Rc6Lumination rx seriesLumination lrc seriesLrc6Lumination lrx seriesRx6 ... Show all