Step 2. Rear Cable Anchor Installation - Lindsay Universal TAU-II Installation Manual

Nchrp 350 tl-3 redirective, non-gating, crash cushion
Table of Contents

Advertisement

U n i v e r s a l T A U - I I
CONCRETE PAD INSTALLATION
Step 2. (Concrete Rear Cable Anchors)
NOTE: IF YOU ARE USING THE COMPACT
BACKSTOP, SKIP TO STEP 3.
P.C.B. Backstop
Use the Cable Anchor Plate as a template for the bolt holes (Right Side)
Use the holes in the plate as a template to mark the
location of the holes for the anchor studs. (There is
one Cable Anchor for each side of the P.C.B.). The
holes should be drilled 6" (150 mm) deep and 7/8"
(22 mm) in diameter. Install the (all thread) studs into
the PCB following the instructions included with the
anchor epoxy. When the epoxy is fully cured, install
the nuts and flat washers. Tighten to 120 ft-lbs (160
N-m).
P.C.B. Backstop
Cable Anchor Bolts (4)
Front
Use the Cable Anchor Plate as a template for the bolt holes (Left Side)
NOTE:
For proper system performance, the
concrete barrier must be rigidly attached to an
adequate foundation.
Anchor Foundation Options and Page 24 for
anchoring material options..
Lindsay Transportation Solutions Sales and Services, Inc (888) 800-3691 [U.S. toll free] or +1 (707) 374-6800
®
C r a s h C u s h i o n
Cable Anchor Bolts (4)
Front
See Appendix "C" for
P A R A L L E L S Y S T E M
ASPHALT INSTALLATION
Step 2. (Asphalt Rear Cable Anchors)
NOTE: IF YOU ARE USING THE COMPACT
BACKSTOP, SKIP TO STEP 3.
PCB Backstop
PCB Backstop
Cable Anchor Bolts (4)
Use the Anchor Plate as a template for the bolt holes (Right Side)
Refer to the Installation Drawings in Appendix "C" to
determine the correct Cable Anchor installation
position. Use the holes in the plate as a template to
mark the location of the holes for the anchor studs.
(There is one Cable Anchor for each side of the
P.C.B.). The holes should be drilled 6" (150 mm)
deep and 7/8" (22 mm) in diameter. Install the (all
thread) studs into the PCB following the instructions
included with the anchor epoxy. When the epoxy is
fully cured, install the nuts and flat washers. Tighten
to 120 ft-lbs (160 N-m)
PCB Asphalt Adapter
Attach the PCB Asphalt Adapter.
Attach the PCB Asphalt Adapter. Drill holes 6" (150
mm) deep and 7/8" (22 mm) in diameter in the
concrete barrier. Drill 15 to 16 ½" (380 to 420 mm) in
the foundation and install 18" (460 mm) anchors
following the instructions included with the anchor
epoxy. When the epoxy is fully cured, install the nuts
and flat washers. Tighten to 120 ft-lbs (160 N-m).
Page 11
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents