HYDRAULIC SYSTEM REQUIREMENTS
Operating Pressure: 1200-2000 PSI (70-140 bar)
Max. Relief Setting: 2100 psi (145 bar)
Flow Range:
Max. Backpressure: 250 psi (17 bar)
Cooling System:
Min. Filtration:
Sound Pressure
Hydraulic Fluids:
Hydraulic Hoses:
CAPACITY
Intake Port:
Discharge Port:
Discharge Capacity: Up to 275 gpm
WEIGHT & CLEARANCE
Weight:
Height:
Width:
WARNING
REL-PS2
5-8 gpm
Required
25 Micron
<85 dBA @ 1m
All hydraulic fluids that meet these listed specifications
or listed HTMA specifications may be used for this tool.
S. U. S.
@ 100
F (38
O
@ 210
F (99
O
FLASH POINT ..................... 340
POUR POINT .......................... -30
2500 psi (175 bar) minimum working pressure (Ref. J517)
H ose assembly should include flush face quick disconnect
couplers as recommended b y the HTMA.
(Hydraulic Tool Manufacturers Association)
1 15/16 in. (49mm)
2" NPFT (51mm)
(Illustration pg 5)
15 lbs.
14" (over handle)
8-1/2" x 9-1/2" diameter
Operation/Safety methods may vary in accordance with the
working guidelines established by each utility or contractor.
For your own safety, ensure that you fully comply with
all safe operation guidelines required by your employer.
Consult your training or safety personnel or supervisor as needed.
7-12 gpm (26-45 lpm)
C) ...........................................140 TO 225
O
C) ....................................... 40 minimum
O
2 3/4 in. (70 mm)
3" NPT (76 mm)
Up to 500 gpm (1,890 lpm)
(Illustration pg 7)
21 lbs. (9.5 kg)
17 in. (over handle)
10W x10.5L (25.4 x 26.7 cm)
12
REL-PS3
F min. (170
C min.)
O
O
F min. (-34
C min.)
O
O