Final Installation Checks; Existing Piping - Toshiba RAV-GM561ATP-E Service Manual

Outdoor unit, digital inverter
Hide thumbs Also See for RAV-GM561ATP-E:
Table of Contents

Advertisement

Placement
Term
location
1 month or more
Outdoors
Less than
1 month
Indoors
Every time

6-6-5 Final Installation Checks

Are there scratches or dents on the existing pipes?
Is it possible to operate the existing air conditioner?
• After the existing air conditioner is operated in cooling
mode for approx. 30 minutes or longer,* recover the
refrigerant
• For cleaning the pipes and recovering oil
• Refrigerant recovery: Pump down method
Was largely discolored ora large quantity of remains
discharged? (When the oil deteriorates, the color of
the oil changes to a muddy or black color.)
Connect the indoor/outdoor units to the existing pipe.
• Use a flare nut attacheindoor/outdoor units. (Do not
existing pipe.)
• Re-machine the flare machining size to size for R32.
In case use existing pipe,The gas pipe Ø19.1 mm is able to use for the outdoor unit of GM80 (3 Hp) or higher,However,
Prior specify to use gas pipe Ø19.1 mm. for the air conditioners

Existing piping

Steps taken to support existing piping
Curing manner
Pinching
Pinching or
Taping
NO
YES
NO
- 39 -
YES
Existing pipes: Cannot be used.
• Use new pipes.
NO
YES
Clean the pipes or use new pipes.
FILE NO. SVM-18043