Trouble-Shooting; Specifications - Sanyo HEC-DR7700C Instruction Manual

Massage lounger
Table of Contents

Advertisement

TROUBLE-SHOOTING

WARNING
If the trouble still persists even after the following proper countermeasures have been taken, stop using the massager
to avoid possible accidents. Disconnect the power plug from the outlet and consult an authorized service center.
Do not attempt to repair the equipment at home by yourself, as it is very dangerous.
Sound and sensation during operation
During use, the following sounds or sensation may be unavoidably generated because
of its structure,
but they are not problems. (They will not affect the function, etc.)
・Rattling sound during tapping
・Noise during UP/DOWN operation of massaging rollers
 and clinking sound during massaging operation
・Creaking sound caused by massaging rollers and cloth
 during massaging operation.
・Gear meshing sound
・Wobbling foot rest
・"Gee" sound when reclined
Type of Trouble
Operation failure
Check that the power plug is securely plugged into
the outlet.
Check that the POWER switch is set to the ON position.
Make sure that no more than one button is being
pressed at any one time.
Courses other than Air Course cannot
Check if the chair is set to the ZERO-G 2.
be selected.
Movement of massaging rollers in upward
This phenomenon is caused by the operation of the timer, but is not a problem.
direction, causing operation to stop
The operation stops in the middle of
When the massaging rollers detach from the body, the
body pressure sensor will work to stop the operation
massaging in the Whole Body Sensor
automatically.
Automatic Course or Automatic Course
The foot rest cannot be extended.
Check if you attempt to adjust the foot rest with the
foot rest slide lever pulled.
The foot rest cannot be stored.
Check that the foot rest is not extended.
You feel discomfort during the operation of
This operation is conducted for safety, but is not a problem.
reclining.
(Move toward to the opposite direction
temporarily, or do not move smoothly.)
The position of massaging rollers
This phenomenon is caused by the adoption of the function of alternative tapping on the right and left
differ between right and left.
sides, but is not a problem.
The display of stiffness differs
Check if your fingers are placed on the sensor.
from the degree of stiffness
The measurement result indicates the stiffness according to the body's biological reaction to the sensor
actually felt.
massage, so it may differ from the stiffness the user actually feels.
Massage in relaxed condition as much as possible during massage. The degree of stiffness may not be
measured correctly when the user massages immediately after taking a bath or is given stimulation other
than sensor massage, like watching TV.
The degree of stiffness cannot
Check your skin for dryness.
be measured correctly.
29
・Sound of air massage
 "Pusshu" sound (Change valve sound)
 Hissing sound (Exhaust sound)
 "Buu" sound (Sound of pump operation)
 "Pako" sound (Sound when the air bag fills)
・When massaging the waist, slight sounds or shock being
 generated from the massaging rollers
・Bouncing movement of the massaging rollers when they
 move from the back to the shoulder
Check points
Countermeasure
Push the power plug into the outlet securely.
(See page 12)
With the LOCK switch set to unlock, turn on
the POWER switch. (See page 12)
Please press each button separately.
After adjusting the angle of back rest, select
the massaging button.
Begin the operation again from the start.
(See page 11)
Adjust the foot rest with the foot rest slide
lever pulled.
Return the foot rest by pulling the foot rest
slide lever.
Place your fingers on the sensor.
Slightly moisten the fingers using hand cream
and place the fingers on the sensor again.

SPECIFICATIONS

Power consumption
Power dissipation of electric heating equipment
Rated time
Timer
Dimensions
Weight
Accessories
Exterior cloth
Kneading frequency
Tapping frequency
Tapping width
Vertical movement speed
Spine stretching width
Range of partial stretching
Vertical stroke length
Height adjustment of massaging rollers
Reclining angle
Reclining method
(See page 16)
Lower body massaging
(Air pressure)
Do not use the massager on other than the designated voltage.
290 W
33 W
30 min.
WHOLE BODY SENSOR AUTOMATIC COURSE・・・Approx. 15 minutes
(Maximum of approx. 20 minutes due to stiffness detection)
AUTOMATIC COURSE・・・・・・・・・・・・・・Approx. 15 minutes
MANUAL COURSE・・・・・・・・・・・・・・・・Approx. 15 minutes
28
/
" [width] × 53
/
" [depth] × 48" [height]
3
1
4
8
* When not reclined (with foot rest retracted)
" [width] × 72
" [depth] × 29
28
/
/
3
7
4
16
* When reclined (with foot rest set horizontally)
Approx. 183 lbs.
Stand, Installation screws (Three)
Synthetic leather
(5 stages) Approx. 10 ∼ 30 times/min.
(5 stages) Approx. 300 ∼ 600 times/min.
(5 stages) Approx. 3 ∼ 5"
One up/down pass in approx. 35 sec.
(5 stages) Approx. 3 ∼ 5"
Partial stretching (Long): Repetition within Approx. 8"
Partial stretching (Short): Repetition within Approx. 4"
Approx. 31"
No gradation or
/
"
/one press of button
3
8
Approx. 120 ∼ 170°
Back rest: Motor-driven type (Linked with foot rest)
Foot rest: Motor-driven type (Foot rest only)
Seat surface: Motor-driven type (Linked with back rest and foot rest)
(3 stages) Approx. 23 ∼ 32 kPa
There is a slight difference according to the part.
/
" [height]
15