The Bollard (Black-10BOLLARDBLK, Bronze-10BOLLARDBRZ & Silver-10BOLLARDSLV) is used for mounting pushplates that activate automatic doors. It will accept BEA’s 4 ½” Square Pushplate, 4 ¾” Square Pushplate, 4 ¾” Panther Pushplate, Dual Vestibule Pushplate and 4 ½” Round Pushplate. The post is made of durable carbon steel and the mounting bracket is made of stainless steel for strength. It can be mounted on either existing concrete or newly poured concrete.
Page 2
Ensure compliance with all applicable safety standards (i.e. ANSI A156.19 / A156.10) upon completion of installation. DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair: 1.
Page 3
5 Installation (Continued) Attach Mounting Bracket Using ‘L’ Shaped Anchors - New Concrete 6” 1. Pour concrete at least 6 inches deep. Attach Post to Mounting Bracket 1. Align post to mounting bracket and attach post to mounting bracket with four post mounting screws. Install Pushplate PUSHPLATE INSTALLATION 1.
Page 4
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.