ECOi Mini 4-6HP 2 Way Inverter Heat Pump VRF Systems
SANYO's policy of product development continues
with the expansion of the ECOi Mini, the 2 pipe
heat pump small VRF system specifically designed
for the European market.
Offering between 11kW and 16kW cooling capacity in 3 sizes
and up to 9 indoor units connected, the ECOi Mini sets new
standards of performance and flexibility.
Utilising R410A and DC inverter technology, SANYO offers
VRF to a new and growing market.
Forming a new key part of the SANYO VRF line up, the ECOi
Mini is compatible with the same indoor units and controls
of the electric and gas powered VRF range.
Features at a glance
• Single phase or three phase power supply
• One AMP start current
• DC inverter technology combined with R410A for excellent
efficiency
• COP of up to 4.34
• Diversity ratio 50-130%
• 150m pipe runs
• Cooling operation to -10°C
• Full range of indoor units and control options
• Compact outdoor unit 1230x940x340mm
HP
Model name
SPW-CR365GXH56B/SPW-CR365GXH8B SPW-CR485GXH56B/SPW-CR485GXH8B SPW-CR605GXH56B/SPW-CR605GXH8B
Power supply
Cooling capacity
kW
Heating capacity
kW
EER Cooling
COP Heating
Running
A
amperes
Cooling
Power input kW
Electric rating
Running
A
Heating
amperes
Power input kW
Recommended fuse size (motor
1ph 3ph
rated)
Dimensions (H/W/D)
mm
Net weight
kg
Air circulation
m
3
/min
Refrigerant amount at shipment
kg
Inches
Gas
(mm)
Piping connection
Inches
Liquid
(mm)
Operating sound normal mode
dB(A)
Operating sound quiet mode
Cooling
Ambient temperature operating
range
Heating
Maximum number of indoor units
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
5
Highest COPs - lowest running costs
HP
4
5
EER Cooling
4.06
3.66
COP Heating
4.34
4.10
Wide operating range
The operating range for heating operation is to -20°C, the
cooling range is to -10°C. The remote controller temperature
setting offers a range from 16°C to 30°C.
4
5
230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz
11.20
14.00
12.50
16.00
4.06
3.66
4.34
4.10
14.1/4.34
19.6/6.02
2.76
3.83
14.7/4.52
19.9/6.13
2.88
3.90
25/16
32/16
1,230x940x340
104
100
3.5
5/8 (15.88)
3/8 (9.52)
51.0
48.0
-10°C DB +43°C DB
-20°C DB +15°C DB
6
8
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
ECOi 2 Way - features at a glance
ECOi
2
Way
is
pump
system
with
features, designed for creating a comfortable
environment when either heating or cooling
is required.
• Heat pump systems offer heating or cooling
• Single footprint size for all unit capacities
• DC inverter technology combined with R410A for excellent
efficiency
• System configuration from 8HP to 48HP
• Diversity ratio 50-130%
• Industry low outdoor unit sound levels: from 54.5dB(A)
• Quiet mode offers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs up to 4.10
6
• Heating capacity to -20°C
3.39
• Connectability of 40 indoor units from 24HP upwards
3.84
• Units available from 8-16HP as single units
Extended compressor life
The compressor running time is monitored and optimised
by a microcomputer to ensure that there is no imbalance
in the operation times of compressors on the same
refrigerant circuit.
Save on piping cost
R410A with low pressure loss enables smaller pipe sizes.
This means reduced piping space, improved workability at
6
the site and reduced piping material costs.
15.50
Extended operating range - better output at lower
17.60
temperatures
3.39
3.84
The operating range for heating has been extended to
23.4/7.18
-15°C. The remote controller temperature setting for heating
4.57
operation has also been extended from 16°C to 30°C.
23.4/7.19
4.58
3/4 (19.05)
52.0
Higher COPs - lower running costs
49.0
HP
8
10
12
9
EER Cooling
3.74
3.54
3.50
COP Heating
4.10
4.10
3.91
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
a
high-performance
heat
excellent
energy-saving
Longer piping means greater installation area
Reducing the refrigerant volume by reducing piping size has
extended the piping actual length to 150m (175m equivalent
piping length).
System difference of
elevation: 50m *
1
Difference in elevation
between indoor units: 15m
*1: 40m if the outdoor unit is below the indoor unit.
*2: Total length of pipe: no more than 300m
14
16
18
20
22
24
26
28
30
32
3.45
3.38
3.63
3.54
3.51
3.49
3.44
3.43
3.41
3.38
3.91
3.79
4.06
4.06
3.97
3.96
3.88
3.84
3.85
3.79
Actual length: 150m *
2
(Equivalent length: 175m)
34
36
38
40
42
44
46
48
3.50
3.47
3.47
3.45
3.42
3.43
3.40
3.38
4.00
3.94
3.89
3.91
3.86
3.83
3.83
3.79
6

Advertisement

loading