Sanyo Cool/Dry Installation Instructions Manual page 12

Sanyo inverter split system air conditioner installation instructions
Table of Contents

Advertisement

05-424 KS0971-1271
12/13/05
WARNING
When connecting each power wire to the corresponding
terminal, follow the instructions "How to connect wiring
to the terminal" and fasten the wire securely tight with
the fixing screw of the terminal plate.
How to connect wiring to the terminal
a) For Indoor Unit
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the wire about 9/32" (7 mm).
See the label (Fig. 28) near the terminal plate.
(2) Using a screwdriver, loosen the terminal screw on
the terminal plate.
(3) Insert the wire and tighten the terminal screw com-
pletely using a screwdriver.
b) For Outdoor Unit
For solid core wiring (or F-cable)
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the solid wire about 15/16" (25
mm). (Fig. 29)
(2) Using a screwdriver, remove the terminal screw(s)
on the terminal plate.
(3) Using the pliers, bend the solid wire to form a loop
suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the termi-
nal plate and fix it securely with the removed termi-
nal screw using a screwdriver.
For stranded wiring
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the stranded wiring about 3/8"
(10 mm) and tightly twist the wire ends. (Figs. 30
and 31)
(2) Using a screwdriver, remove the terminal screw(s)
on the terminal plate.
(3) Using a ring connector fastener or pliers, securely
clamp each stripped wire end with a ring connector.
(Fig. 30)
(4) Place the ring connector wire, and replace and
tighten the removed terminal screw using a screw-
driver. (Fig. 32)
1:28 PM
Page 12
Loose wiring may cause the
terminal to overheat or result
in unit malfunction. A fire
hazard may also exist. There-
fore, be sure all wiring is
tightly connected.
STRIP
SIZE
Solid wire
Insulation
Stranded wire
Twist wire ends
Special
Screw
washer
Ring connector
Terminal plate
Wire
12
9/32"
(7 mm) (ACTUAL
SIZE)
Fig. 28
Loop
Fig. 29
Ring
connector
Fig. 30
Fig. 31
Screw and
special washer
Ring
connector
Wire
Fig. 32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

09kls7112kls7112ks71C0971Cl0971,c1271 ... Show all

Table of Contents