System: 12XLS71
Ceiling Recessed Low Ambient Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
Fuse Size, Max.
Compressor
DC Rotary Inverter
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
(HIGH))
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.))
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High))
No. Poles
No. Motors
(Hi/Med/Low)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.))
Tube Size
Drain Connection Size
Indoor/Outdoor: XS1271/CL1271
Grille: PNR-XS1872
General Data (at 115V)
115/1/60
(A)
(A)
(A)
12.6-20
(W)
Propeller
15-3/4-1
DC Motor
(RPM)
8-750
(W)
(A)
Aluminum Fin and Copper Pipe
Corrugated Plate-Inner Rif ed
2-18.1
(in.)
5/16"
12-5/8/5-3/4-1
3+Auto
8-470
(W)
235/206/194
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate & Inner Rif ed
2-18.1
(in.)
(in.)
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
20
20
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
20
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
50-1
1059
Outdoor Unit
0.6
Weight
Net
Shipping
3.95
Shipping Volume
Performance Data @ ARI Standard Conditions (115V)
Turbo
Cooling
Total Capacity
Sensible Capacity
30-1
Latent Capacity
SEER
Dehumidification
34
.346
Amps
Power Inputs
Outdoor Sound Rating
2.94
9-32"
Electric Expansion Valve
(in O.D. Dishcharge)
(in O.D. Suction)
(in.)
(uncrated)
11-1/16 x 22-5/8 x 22-5/8
(crated)
11-13/32 x 24-13/16 x 28-1/8
(uncrated) 21-9/16 x 28-11/32 x 10-1/16
(crated)
23-5/8 x 33-11/16 x 14-1/4
Indoor
Outdoor
(lbs.) 35.3
(lbs.) 41.9
(cu.ft.) 4.59
(BTU/H)
11,900 (3,000-11,900)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
12.6 (2.5-12.6)
(W)
1260 (250-1260)
(dB-A)
Print Form
R410A
2.43
Flare
65
23
1/4"
3/8"
H x W x D
77.2
83.8
6.35
7,200
4,700
16
4.26
51

Advertisement

loading

Summary of Contents for Sanyo 12XLS71

  • Page 1 Split System Submittal Data System: 12XLS71 Indoor/Outdoor: XS1271/CL1271 Grille: PNR-XS1872 Ceiling Recessed Low Ambient Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 115V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor DC Rotary Inverter No.
  • Page 2: Operating Range

    Less than 31/32 Less than 31/32 24-19/32 (625) 14-3/32 (358) 2-3/32 25/32 1-27/32 1-3/32 Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com Options Refrigerant Line Set Microprocessor Fresh Air Intake Airduct Extension...

This manual is also suitable for:

Xs1271Cl1271