5. Trouble   S hooting   & FAQ
#  
Issue  
1  
Fan  
won't  
run,   and   no  
12V   o utput  
2  
The   fan   is  
running,   but  
there   is   no  
12V   o utput.  
3  
After   a   few  
minutes,   the  
PSU  
stops  
working,  
starts  
working,  
stops  working  
and  
keeps  
cycling.  
4  
Output  
is  
normal,   but  
the   fan   is   not  
working.  
5  
The  
PSU  
suddenly   has  
no  
output  
and   can't   be  
started   a gain.  
  P SU
Reason  
Troubleshooting  
AC   Input   is  
1. Make   sure   the   AC   input   wire   has   a   good
abnormal  
connection   a nd   t he   p lugs   a re   c onnected   f irmly
2. Make   s ure   t he   m ains   p ower   i s   w orking   w ell   a nd   i ts
voltage   i s   a bove   1 00V.
1. Voltage   in
1. Please   check   whether   the   voltage   is   above   100V
your  
power
with   m ultimeter   t o   m ake   s ure   t he   P SU   c an   s witch   o n
system  is  lower
correctly.
than   r equired
2. Check   whether   there   is   a   short   circuit   output   or
2. PSU   is   in
overload   that   is   causing   the   PSU   to   enter   a   locked
protection
status.  After  removing  the  problem,  the  PSU  should
mode
power   u p.
PSU  
is  
in  
1.Check   w hether   t he   f an   i s   w orking
over-­‐heat  
2.Check   w hether   t he   f an's   v ent   i s   b eing   b locked
protection  
3.Check  whether  there  is  a  dust  buildup  inside  the
PSU   d ue   t o   p rolonged   u se.   D o   N OT   r emove   t he   P SU's
cover   u nless   t rained   t o   d o   s o.
4 . Check   the   power   and   ambient   temperatures
follows   t he   L oad/Temperature   g raph
Fan   i s   b roken  
1. Check   t hat   t he   f an   i s   c lear   o f   b lockages   o r   b uildup
2. Fan   i s   b roken   a nd   n eeds   t o   b e   r eplaced.
Check   whether   the   load   current   has   exceeded   the  
The   PSU   is   in  
built-­‐in   overcurrent   protection   limit.   The   protection  
over-­‐current  
automatically   triggers   when   the   load   current  
protection.    
exceeds   the   limit   to   protect   against   damage   to   the  
PSU   a nd   t he   s erver.    