Technical Data
Number of outputs
Output switching ratings
Ohmic load
Capacitive load
Voltage
Maximum inrush current
Maximum load
Incandescent lamps
Halogen lamps 230V
Halogen lamps, electronic transformer**
Fluorescent lamps, not compensated
Fluorescent lamps, parallel comp.
Max. number of electronic transformers
Output life expectancy (mechanical)
Permitted wire gauge
Screw terminal
KNX busconnection terminal
Power supply
Power consumption KNX bus typ.
Power consumption mains 230VAC typ.
Operation temperature range
Enclosure
Dimensions MDRC (Space Units)
*
total current carrying capacity neighbouring outputs max. 32 A
**
low voltage halogen lamps with electronic transformer
*** from Q4 2012 Power consumption KNX bus < 0,3W, Power supply mains 230VAC not longer required
Examplary circuit diagram AKI-0816.01
Note: AKI/AKS 08/12: Power supply 230VAC, from Q3 2012 via KNX Bus.
51766 Engelskirchen
MDT technologies GmbH
Tel.: + 49 - 2263 - 880
Fax: + 49 - 2263 - 4588
Stand: 1012
MDT Switch Actuator AKI
AKI-0416.01
4
16A/20A*
max. 200uF at 16A
230VAC
600A/150µs
300A/600µs
3680W
3680W
2500W
3680W
2500W
28
1.000.000
0,5 - 4,0mm² solid core
0,5 - 2,5mm² inely stranded
0,8mm Ø, solid core
KNX bus
< 0,25W
--
0 to + 45°C
IP 20
4SU
Papiermühle 1
knx@mdt.de
www.mdt.de
AKI-0816.01
8
16A/20A*
max. 200uF at 16A
230VAC
600A/150µs
300A/600µs
3680W
3680W
2500W
3680W
2500W
28
1.000.000
0,5 - 4,0mm² solid core
0,5 - 2,5mm² inely stranded
0,8mm Ø, solid core
KNX bus
< 0,25W
--
0 to + 45°C
IP 20
8SU
N
AKI-1216.01
12
16A/20A*
max. 200uF at 16A
230VAC
600A/150µs
300A/600µs
3680W
3680W
2500W
3680W
2500W
28
1.000.000
0,5 - 4,0mm² solid core
0,5 - 2,5mm² inely stranded
0,8mm Ø, solid core
230VAC/50Hz
< 0,15W***
< 0,3W***
0 to + 45°C
IP 20
12SU
DIN EN ISO 9001
TAW Cert
Zert.Nr.1905606