3.3 ELECTRO PNEUMATIC UNIT (EPU)

Electrical supply
Power consumption
Air supply
Ambient temperature
Humidity range
Protection class
Mounting
Output signals
Communication
Pump start/stop signal
Pneumatic supply
Cable glands
(1) Mains supply
(2) Communication to MCU
(3) Pump starter box
(4) Ballast skid
(5) Flowmeter dP/I
(6) Spare
Wire size supply-connectors
Wire size output-connectors
Wire size input-connectors
Installation category
Pollution degree
Ventilation requirements
USB Flash drive with a type A connector
USB 1.0 compatible and formatted according to FAT16
-
NO/NC contact, rating 250 VAC – 5 A or 30 VDC – 5 A
NO/NC contact, rating 250 VAC – 5 A or 30 VDC – 5 A
NO/NC contact, rating 250 VAC – 5 A or 30 VDC – 5 A
NO/NC contact, rating 250 VAC – 5 A or 30 VDC – 5 A
NO/NC contact, rating 250 VAC – 5 A or 30 VDC – 5 A
115/230 VAC, 50/60 Hz
60 W
4 – 7 bar, dry clean air (0,4 MPa – 0,7 MPa)
average consumption 6 l/min
max. consumption 50 l/min
-20 °C – +55 ºC
0 – 95 % RH
IP 65
wall mounting, see drawing 0806-1287 for dimensions
RS422/485 to MCU
24 VDC, to sample pump starter relay
4 bar to skid and sample valve
See drawing 0806-2050 for options
M20 x 1,5 (cable diameter 6 – 12 mm)
M20 x 1,5 (cable diameter 6 – 12 mm)
M20 x 1,5 (cable diameter 6 – 12 mm)
M20 x 1,5 (cable diameter 10 – 14 mm)
M20 x 1,5 (cable diameter 6 – 12 mm)
M20 x 1,5 (cable diameter 6 – 12 mm)
Min-max
0,2 – 2,5 mm
Min-max
0,2 – 2,5 mm
Min-max
0,5 – 4,0 mm
II
II acc. To IEC 664
no special requirements
2
2
2
15