Page 2
The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. CLEARVIEW shall have no liability for any error or damage of any kind resulting from the use of this document.
Chapter 1 Introduction 1.1 Product Overview KR423I is a professional high integration device which includes encoding, multiplexing, scrambling and DVB-C/T modulation. It supports 12 HDMI (8 HDMI optional) input, one DVB-C tuner input and 128 IP input with Data1(GE) and Data2(FE) port.
KR423I Encoder Modualtor User Manual Bandwidth 6M, 7M, 8M Constellation QPSK, 16QAM, 64QAM Guard Interval 1/4, 1/8, 1/16, 1/32 1/2, 2/3, 3/4, 5/6, 7/8 ≥42 dB RF frequency 50~960MHz, 1KHz step 4*RF COFDM DVB-T out (4 carriers RF out combined output) RF output -28~ -3 dBm (77~97 dbµV), 0.1db step...
Page 8
KR423I Encoder Modulator User Manual DVB-T RF out 1.5 Appearance and Description Front and Rear Panel Illustration RF test and RF out port Port Power supply and Grounding Pole 12HDMI input Reset Key/Data Port Indicator Indicator ASI output port(optional) Page 4 / 29...
Page 9
KR423I Encoder Modualtor User Manual DATA Port (for IP stream input/output) NMS/CAS RF in and Loop out ClearView Corp. Ltd. Page 5 / 29...
KR423I Encoder Modulator User Manual Chapter 2 Installation Guide This section is to explain the cautions the users must know in some case that possible injure may bring to users when it’s used or installed. For this reason, please read all details here and make in mind before installing or using the product.
KR423I Encoder Modualtor User Manual 1.2~1.5m and the distance against wall should be no less than 0.8m. Electric Isolation, Dust Free Volume resistivity ground anti-static material: Machine Hall Floor ,Grounding current limiting resistance: 1M 1X10 ~1X10 (Floor bearing should be greater than 450Kg/㎡) 5~40℃(sustainable ),0~45℃(short time),...
KR423I Encoder Modulator User Manual Chapter 3 WEB NMS Operation User not only can use front buttons to set configuration, but also can control and set the configuration in computer by connecting the device to web NMS Port. User should ensure that the computer’s IP address is different from the NDS3542’s IP address;...
KR423I Encoder Modualtor User Manual 4.2 Encoder Operation Status When we login into encoder module, it displays the status interface as Figure-2. Current software version information User can click any item here to enter the corresponding interface to check information or set the parameters.
Page 14
KR423I Encoder Modulator User Manual General settings for the Encoding program: User can edit any item listed as needed. Video Status read area Figure-3 Parameters → TS Config: From the menu on left side of the webpage, clicking “TS Config”, it displays the interface where users can configure the TS output parameters.
Page 15
KR423I Encoder Modualtor User Manual Input Area Output Area Operation Area Figure-4 Configure ‘Input Area’ and ‘Output Area’ with buttons in ‘Operation Area’. Instructions are as below: : To add input channel which can from GE1/GE2/Connector : To edit the input channel...
Page 16
KR423I Encoder Modulator User Manual Similarly, user can cancel the multiplexed programs from the right box. To select all the input programs To select all the output programs To parse programs time limitation of parsing input programs ➢ Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’...
Page 17
KR423I Encoder Modualtor User Manual Figure-6 ➢ TS Config→PID Bypass: From the TS Config menu on up side of the webpage, clicking “PID Bypass”, it displays the interface as Figure-7 where user can add PIDs to be passed, click the “+” symbol, input current IP channel number, then input current IP source Pid and output Pid which is customer needed , then click “set”...
Page 18
KR423I Encoder Modulator User Manual Figure-7 Parameters → Modulator: From the menu on left side of the webpage, clicking “Modulator”, it will display the Modulator Configuration screen as Figure-8. Here user can set modulation parameters. Figure-8 Page 14 / 29...
Page 19
KR423I Encoder Modualtor User Manual Parameters → IP Stream: KR423Isupports TS to output in IP (4*MPTS) format through the DATA1 port. Click ‘IP Stream’, it will display the interface where to set IP out parameters (Figure-9). Quickly Config Channel Config Figure-9 Parameters→...
Page 20
KR423I Encoder Modulator User Manual Select to configure logo, caption or QRcode Select program1/2/3/4 of Module1/2/3 to apply the logo insertion, or you can select all to apply all programs and all modules Click here to comfirm the LOGO you selected...
Page 21
KR423I Encoder Modualtor User Manual Put your QRcode URL here Put your QRcode everywhere Browse and select QRcode which has been created Figure-12 System → Network: Click ‘Network’, it will display the interface as Figure-13 where to set network parameters.
Page 22
KR423I Encoder Modulator User Manual Figure-13 System → password From the menu on left side of the webpage, clicking “Password”, it will display the screen as Figure-14 where to set the login account and password for the web NMS. Page 18 / 29...
Page 23
KR423I Encoder Modualtor User Manual Figure-14 System → Configuration: From the menu on left side of the webpage, clicking “Configuration”, it will display the screen as Figure-15 where to save/ restore/factory setting/ backup/ load your configurations. ClearView Corp. Ltd. Page 19 / 29...
Page 24
KR423I Encoder Modulator User Manual Figure-15 System → Firmware: From the menu on left side of the webpage, clicking “Firmware”, it will display the screen as Figure-16 where to update firmware for the modulator. Page 20 / 29 ClearView Corp. Ltd.
Page 25
KR423I Encoder Modualtor User Manual Figure-16 System→ Date/Time: From the menu on left side of the webpage, clicking “Date/Time”, it will display the screen as Figure-17 where to set date and time for the device. ClearView Corp. Ltd. Page 21 / 29...
Page 26
KR423I Encoder Modulator User Manual Figure-17 System→ Log: From the menu on left side of the webpage, clicking “Log”, it will display the log interface as Figure-18 where to check or export the Kernel/System log. Page 22 / 29 ClearView Corp. Ltd.
CLEARVIEW’s ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All CLEARVIEW products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by CLEARVIEW.