2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health &...
5. Operating Principle KOBOLD Piston Flow Meters are direct volume counters, also called displacement counter (positive displacement meter). Its function is based on continuous limitation of a definite part-volume of the flow in a measuring cell through continuous filling and emptying of this measuring cell.
6. Mechanical Connection Before installation: Remove all packing materials, transport retainers and ensure that no such materials remain in the device. Make sure that the maximum operating pressure and temperature of the device are not exceeded. Please ascertain, that the pipe system is free of any welding bead, ferrite particles or other pollution.
8. Technical Information Measuring range: 6-420 L/h Max. flow rate: 600 L/h Measuring accuracy: ± 1.0% of reading ± 2.5% of reading Repeatability: ± 0.2% Standard viscosity range: 5-100 mm Process temperature: max. 80 °C Ambient temperature: -10 to +60 °C Max.
Frequency output with frequency divider (...F3X0) Power supply: 24 VDC ± 20% Supply current: 15 mA Pulse output: PNP, open collector, max. 25 mA Electr. connection: plug connector M12x1 Division factor: 1:2, 1:4 or customer request Analogue output (...L303; ...L343) Power supply: 24 V ±20%...
12. EU Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Piston Flow Meters Model: DRZ to which this declaration relates is in conformity with the standards noted below: EN 61000-6-3:2011 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission...