Maximum Power Consumption; Operating Environment; Wall-Mounting Screws - Honeywell Sensepoint XCL Installation Manual

Fixed gas detector
Hide thumbs Also See for Sensepoint XCL:
Table of Contents

Advertisement

Maximum Power Consumption

Operating Environment

Wall-Mounting Screws

The power consumption varies, depending on output mode and sensor
type. The total power consumption for two relay outputs is 0.6 W.
Analog Output Mode
Electrochemical-cell-type sensors
Catalytic-type sensors
Infrared-type sensors
Digital Output Mode
Electrochemical-cell-type sensors
Catalytic-type sensors
Infrared-type sensors
Operating temperature
Storage temperature
Humidity
Atmospheric pressure
Altitude
Installation category
Pollution degree
NOTE
Sensepoint XCL is designed to be installed indoors only.
Thread diameter
Length
In normal state
0.5 W
1 W
1 W
In normal state
0.2 W
0.7 W
0.7 W
−20 to 50°C
0 to 30°C
0 to 100% (non-condensing)
90 to 110 kPa
Lower than 2000 m
II (UL/CSA/IEC/EN 61010-1)
2 (UL/CSA/IEC/EN 61010-1)
4 mm
longer than 25 mm
Introduction
During an alarm
1.2 W
1.7 W
1.7 W
During an alarm
0.7 W
1.2 W
1.2 W