WARNING
!
Serious or fatal electric shock may result from failure to connect the Inline System to the service entrance ground. Also ground
metal plumbing and all other metal near the Inline System. When grounding these components, use a wire no smaller than the
power supply wires from the circuit breaker to the Inline System. To reduce the risk of electric shock, disconnect power before
working on or around the water system.
CAPACITORS INSIDE THE INLINE SYSTEM CONTROLLER CAN STILL HOLD LETHAL VOLTAGE EVEN AFTER POWER HAS
BEEN DISCONNECTED. ALLOW 5 MINUTES FOR DANGEROUS INTERNAL VOLTAGE TO DISCHARGE BEFORE REMOVING
ACCESS PANEL.
This pump has not been investigated for use in swimming pool or marine areas.
Installation Procedure Wiring
1. Disconnect electrical power at the main breaker.
2. Verify that the dedicated branch circuit for the Inline System is equipped with a 15 amp
Listed fuse/Listed circuit breaker.
3. Remove the access panel of the Inline System by removing the four access panel screws as
shown in FIGURE 1.
4. For your convenience, the pressure sensor has been pre-wired inside the unit. The red and
black wires are attached to the pressure sensor inputs, and the white and green wires are
connected to the pressure shut-off sensor input (optional). See FIGURES 3 and 4 showing
the sensor connections.
5. If mounting or in wet environments, a liquid-tight conduit fitting and liquid-tight conduit are
required (not supplied) to ensure that the enclosure maintains a watertight NEMA 4 rating.
Install the liquid-tight conduit fitting into the conduit hole in front of the L1, L2 line connector
(FIGURE 3).
FIGURE 3:
Inline Constant Pressure System
ON
1. Underload
2. Steady FLow
1
2 3 4
OFF
OVER
PRESSURE
TEMPERATURE
SENSOR
SWITCH
GROUND
L1
L2
11