OPERATION PRINCIPLES BY PARTS OF CIRCUIT
5-11) OPTION Circuit
G
This circuit operates with the initial power on, uses DIODE (1N4148) or JUMPER WIRE.
To modify option circuit, Power must be turned off before modification and turned on after the modification.
Refer to the table below, the default factory values are highly recommended unless exceptional cases.
OP11, OP12
OP11
*
Jumper USE OP2 < Water Fill Time Control Option >
D601
*
Diode(1N4148) USE
OP12
MODEL
RS2 * 11
RS2 * 21
RS2 * 31
D602
Fill Time
5 Sec
6 Sec
7 Sec
10 Sec
25
FUNTION
No Cruch, 3 Step, Light
Cruch, 3 Step, Light
Cruch, 5 Step, P/F, L/T Lock, Filter, Indicator
Remark
Flow Sensor Not USE