Installation Space - LG AHNW166T0 Installation Manual

Table of Contents

Advertisement

Installation
3. When installing the outdoor unit in a place that is constantly exposed to a strong wind like a coast
or on a high story of a building, secure a normal fan operation by using a duct or a wind shield.
• Install the unit so that its discharge port faces to the wall of the building.
Keep a distance 500mm or more between the unit and the wall surface.
• Supposing the wind direction during the operation season of the air conditioner, install the unit
so that the discharge port is set at right angle to the wind direction.
Air inlet grille

Installation Space

1) Indoor Unit
• The following values are the least space for installation. If any service area is needed for service
according to field circumstance, obtain enough service space.
• The unit of values is mm.
300
Service space
(left side)
12
500
520
400
Piping space
(front side)
Service space
(front side)
(Unit: mm)
Strong
wind
Blown
air
330
600
space
H-Beam supporter
Strong
wind
(Unit: mm)