Dunkirk D247 Installation Instructions Manual page 23

Gas-fired steam or vvater boiler
Table of Contents

Advertisement

I
I
I
I
I
TURN GAS SUPPLY OFF.
TURN THERMOSTAT
(CONTROLLER)
TO CALL
FOR HEAT
POWER TO MODULE
(24V MODULE)
S8600 INTERMITTENT
PILOT SYSTEM
TROUBLESHOOTING
TABLE
START
I
NOTE: Before troubleshooting,
familiarize
yourself with the startup and check procedure.
Check line voltage power, low voltage transformer,
limit controller, thermostat
(controller) I
and wiring.
Also, check air proving switch on combustion air blower system (if used) and
that vent damper (if used) is open and end switch is made.
I
YES ,
SPARK ACROSS
IGNITER/SENSOR
GAP
YES
1
TURN GAS SUPPLY ON
PILOT BURNER LIGHTS?
YES
1
SPARK STOPS WHEN
PILOT IS LIT?
YES
r
MAIN BURNER LIGHTS?
SYSTEM RUNS UNTIL
CALL FOR HEAT ENDS
YES
r
I
CALL FOR HEAT ENDS
SYSTEM SHUTS OFF?
I
YES J ,
TROUBLESHOOTING
ENDS
Pull ignition lead and check
,,_ _
'_
On models with vent damper plug,
spark at module.
_f
make sure vent damper has not
been installed, then removed.
Spark okay?
Replace vent damper if necessary.
YES
Jr
On other models, replace module.
¥
I
Check ignition cable, ground wiring, ceramic insulator and gap, and correct.
I
Check boot of the ignition cable for signs of melting or bucking.
Take protective
I
action to shield cable and boot from excessive temperatures.
Check that all manual
valves are
supply tubing and
are
gas
open,
pressures
good, and pilot burner orifice is not blocked.
Check electrical connection between module and pilot operator on gas control.
Check for 24 Vac across PV-MV/PV terminals on module.
If voltage is okay,
replace gas control: if not, replace module.
NOTE: If S8600B, H goes into lockout, reset system.
For S8600M, wait 6 min. nom.
for retry or reset system.
Check continuity of ignition cable and ground wire.
Clean flame rod.
Check electrical connections
between flame rod and module.
Check for cracked ceramic flame rod insulator.
Check that pilot flame covers flame rod and is steady and blue.
Adjust pilot flame.
If problem persists, replace module.
Check for 24 Mac across MV-MV/PV terminals.
If no voltage, replace module.
Check electrical connections
between module and gas control.
If okay, replace
gas control or gas control operator.
I
NOTE: If S8600B, H; $8610B, H goes into lockout, reset system.
For S8600M, wait
6 min. nom. For retry or reset system.
Check continuity of ignition cable and ground wire.
NOTE: If ground is poor or erratic, shutdowns may occur occasionally
even though operation is normal at the time of checkout.
Check that pilot flame covers flame rod and is steady and blue.
If checks okay, replace module.
Check for proper thermostat (controller) operation.
Remove MV lead at module: if valve closes, recheck temperature controller and
wiring: if not, replace gas control.
I
I
Repeat procedure
until trouble free operation is obtained.