echoflex Elaho Dual Tech Ceiling-mount Vacancy Sensor Installation Manual

Advertisement

Quick Links

Echoflex Installation Guide
Elaho Dual Tech Ceiling-mount Vacancy Sensor
Overview
The Elaho Dual Tech Ceiling-mount Vacancy Sensor uses passive infrared (PIR)
technology and acoustic detection to provide reliable vacancy sensing for
lighting control. The sensor relies on local station control for manual on and
provides auto off functionality upon detection of vacancy.
The ceiling-mount sensor offers 360 degree coverage with optimized lens
options to accommodate small and large spaces. The sensor is available in a
white or black finish.
Field-installed lens masks are provided to allow customized detection fields
for each sensor lens type.
Custom Configuration
This document guides you through the installation and local DIP switch setup
of the sensor.
For more detailed information about custom configuration options available
using ElahoAccess, see the ElahoAccess Mobile App integrated help system.
Note:
switch 2 must be enabled. See
Main Offic e
Squamish, BC, Canada
n
Email
info@echoflexsolutions.com
© 2018 Echoflex Solutions, Inc.
8186M2184
Revision A
Released 2018-09
n
n
To use the configuration settings applied using ElahoAccess, DIP
Toll Free +888 324 6359
n
Web:
echoflexsolutions.com
n
Echoflex intends this document to be provided in its entirety.
n
Small Room Lens - coverage
2
452 ft
at 8 ft (42 m
2
804 ft
at 10 ft (74.3 m
Large Room Lens - coverage
2
1,809 ft
at 8 ft (168 m
2
3,019 ft
at 10 ft (280 m
DIP Switch Settings on page 7
Phone +778 733 0111
n
Product information and specifications subject to change.
n
2
at 2.4 m)
at 3 m)
2
2
at 2.4 m)
2
at 3 m)
.
Fax +604 815 0078
n

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elaho Dual Tech Ceiling-mount Vacancy Sensor and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for echoflex Elaho Dual Tech Ceiling-mount Vacancy Sensor

  • Page 1 Elaho Dual Tech Ceiling-mount Vacancy Sensor Overview The Elaho Dual Tech Ceiling-mount Vacancy Sensor uses passive infrared (PIR) technology and acoustic detection to provide reliable vacancy sensing for lighting control. The sensor relies on local station control for manual on and provides auto off functionality upon detection of vacancy.
  • Page 2: Prepare For Installation

    UL/cUL listed, complies with UL508A, UL916, and CSA C22.2 No. 14 • CE compliant • For use with Echoflex dimming and relay products. Environment Ambient For indoor, commercial controls use only. Indoor installation only. The sensor operates in ambient temperatures of -10°C to 40°C, with a maximum of 90% non-condensing humidity.
  • Page 3: Control Wire Specification

    EchoConnect is a bidirectional protocol that uses one pair of wires (data + and data -) for both data and power. Echoflex recommends using Belden 8471 (or approved equal) Class 2 wire. The total combined length of an EchoConnect wire run (using Belden 8471, or equal) may not exceed 1,640 feet (500 m).
  • Page 4: Installation

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Installation Installation should follow all local codes and standard electrical practices. Note: NEC Class 2 product to be wired in accordance to NEC Article 725 and local jurisdiction requirements. The ceiling-mount sensor is provided with a mounting plate that can be mounted to a junction box, finished ceiling, or soft ceiling tile.
  • Page 5: Soft Ceiling Tile Installation

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Soft Ceiling Tile Installation Ceiling tile adapter Ceiling tile Ceiling tile adapter Pull the Belden 8471 (or equivalent) and 14 AWG (2.5 mm ) ground wire to the mounting location and strip each wire to the appropriate length.
  • Page 6: Sensor Configuration

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Sensor Configuration The Elaho Dual Tech Ceiling-mount Vacancy Sensor participates in an Elaho control system using the configured Space and Address, which are selectable using the rotary switches on the sensor electronics located behind the removable cover.
  • Page 7: Dip Switch Settings

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor DIP Switch Settings DIP switches on the sensor electronics provide for additional configuration options including Use Custom Config, Vacancy Timeout, Enable/Disable detection LEDs, PIR Only, and the ability to restore the sensor to its factory defaults.
  • Page 8: Power Up And Test

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Power Up and Test Power Up All EchoConnect terminations in the system must be made before applying power to the system and sensor. When the sensor is powered up, the PIR and acoustic detection LEDs illuminate for one minute for calibration and warm- up, then return to normal operation according to the configuration.
  • Page 9: Vacancy Timeout

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Vacancy Timeout Vacancy timeout is the amount of time the sensor waits to take action after no movement is detected. By default, vacancy timeout is set to 15 minutes (indicated by DIP switch 3 set to Off and 4 set to On; see...
  • Page 10: Lens Masking

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Walk Test The sensor offers a Walk Test mode, which shortens the vacancy timer to ten seconds and allows for simple and quick verification of the sensor’s coverage and range in the installed space.
  • Page 11: Sensor Coverage

    Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Sensor Coverage Small Room Lens Side View 8 ft 2.4 m 10 ft 3.0 m 12 ft 3.7 m 20 ft 20 ft 15 ft 10 ft 5 ft 5 ft 10 ft 15 ft 6.1 m...
  • Page 12 Echoflex Installation Guide Dual Tech Ceiling-mount Vacancy Sensor Dual Tech Ceiling-mount Vacancy Sensor Page 12 of 12 Echoflex Solutions, Inc.

This manual is also suitable for:

Elaho dual tech ceiling-mount occupancy sensor

Table of Contents