Unit leaks water
Possible cause
Unit is not level
Drain line clogged or kinked
Drain is clogged, preventing water from escaping
Drain line does not have a downward slope
Coil is iced, causing excess condensation
Unit runs but does not cool
Possible cause
Lack of air flow/heat exhaust (outer room)
Fans run but compressor does not
Unit undersized
Evaporator fan runs but compressor does not
Possible cause
Compressor and/or starting components faulty
Fans run but compressor does not
Compressor runs; evaporator fan does not
Possible cause
Faulty fan motor
Faulty fan relay
Compressor short cycles
Possible cause
Compressor and /or starting components faulty
Humidity in cellar is too high
Possible cause
Cellar vapor barrier not sufficient
Page 18
TROUBLESHOOTING GUIDE
Solution
Unit should be level in wall to prevent leakage
Check drain line to make sure water can flow freely
1. Disconnect exterior drain line and clear it out; run provided drain line
brush through the drain port and into the interior drain line.
2. Open access port and, using a flashlight, check drain line for blockage;
drop a pan tab into the drip tray to prevent further blockages.
Fix drain line so there is a downward slope from the unit to the drain
Melt ice with blow drier. Soak up with a towel.
Solution
Make sure fans are unobstructed; clean evaporator if necessary
Compressor may have overheated. Shut unit off for 1 hour to allow compres-
sor to cool. Turn back on and check for cooler air flow out. If compressor runs,
check for and clean condenser coil as possible cause of compressor overheat-
ing. If problem repeats, call Technical Support 1-800-648-6058
Order correctly sized unit
Solution
Call Technical Support at 1-800-648-6058
Compressor may have overheated. Shut unit off for 1 hour to allow compres-
sor to cool. Turn back on and check for cooler air flow out. If compressor runs,
check for and clean condenser coil as possible cause of compressor overheat-
ing. If problem repeats, call Technical Support.
Solution
Call Technical Support at 1-800-648-6058
Call Technical Support at 1-800-648-6058
Solution
Call Technical Support at 1-800-648-6058
Solution
Install proper vapor barrier