Drain Line - N'Finity 3000 User Manual

N'finity 3000 wine cellar cooling unit
Hide thumbs Also See for 3000:
Table of Contents

Advertisement

Condensation Drain Line Tube
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It is
important that the drain line tube be properly connected and used to prevent leakage and other problems associated with
excess condensation.
Failure to use the condensation drain line tube will void the warranty on the unit.
To attach the drain line tube:
1. Wrap tee with Teflon tape one or two
turns clockwise.
2. Next, thread the barb tee into the rear
drain port and rotate until tight. Make
sure the tees of the barb are sticking
straight up and down.
3. Next, attach the piece of 1/2" ID clear
plastic tubing to the lower tee of the
barb.
4. Every six weeks, disconnect the drain
line from the barb tee. Remove the barb
from the rear drain port and clean it.
Then use the supplied drain line brush
to clean the interior drain line. Use
the drain line access door (pictured at
right) to drop a pan tab into the drip
tray to prevent the buildup of microbial
growth.
*
INCORRECT: Do not allow
drain line to be submerged (if
draining into a vessel).
Drain Line Connection
It is important that the drain line tube be properly connected and used to prevent leakage and other problems associated
with excess condensation. If the drain line is draining into a vessel, make sure that the drain line hangs above the surface
and is not submerged. This will prevent the formation of mold.
www.wineenthusiast.com

DRAIN LINE

Access door
*
CORRECT: Drain line should
hang above the water line.
Page 11