Description Of The Charging Cycle; Regenerating/Recharging Fully Discharged 12 V Batteries (Regeneration Mode) - Medion AutoXS MD 18559 User Manual

Table of Contents

Advertisement

− Press the MODE
mode.
The
9
symbol is displayed.
If you do not then set another mode, the electronics automatically start the charging
process with a charging current of around 3.8 A.
Once the battery is fully charged, the frame around the battery icon
and the entire battery icon lights up continuously. Trickle charging takes place in this
state.
Regenerating/recharging fully discharged 12 V batteries
(regeneration mode)
− Connect the fully discharged battery to the charger and start the charging
process.
In this regeneration mode, the battery is charged until the charger measures a
terminal voltage that is high enough for a regular charging mode. The appliance then
switches automatically to an appropriate charging mode and continues charging.

Description of the charging cycle

Charging mode
6 V / 0.8 A
12 V / 0.8 A
button several times to select the 12 V / 3.8 A COLD
1
Charging step
Fully charged
Changeover to trickle
charging
Continuation of the
charging process
Fully charged
Changeover to trickle
charging

Description of the charging cycle

Battery voltage
At a battery voltage from 3.7 to 7.6 V,
the charging process takes place
with a charging current of 0.8 A
At a battery voltage ≥ 6.4 V, the
battery is kept at the fully charged
level with a trickle charging current
of 50–150 mA (0.05–0.15 A).
At a battery voltage of < 6.4 V, the
charging process continues with a
charging current of 0.8 A.
At a battery voltage from 7.5 to 15.1 V,
the charging process takes place
with a charging current of 0.8 A
At a battery voltage ≥ 12.8 V, the
battery is kept at the fully charged
level with a trickle charging current
of 50–150 mA (0.05–0.15 A).
11
stops fl ashing
21