Select Charging Mode - Medion Battery Charger Manual

Table of Contents

Advertisement

11265 Battery Charger UK.fm Seite 13 Montag, 7. Mai 2007 12:32 12

SELECT CHARGING MODE

Select a charging mode depending on the battery type and
environmental temperature. You can also recharge a
completely discharged battery ("regeneration").
The charger's electronics do not start the charging process
directly after connecting the battery but rather only after a
charging mode has been selected. This avoids sparks that
often occur during the connection process.
• In order to select a charging mode press the MODE button
several times. The LED for the relevant mode lights up.
• The charger recognises the modes suitable for the battery
type. Therefore not every mode can be selected for every
battery.
• After selecting a mode the charger implements it. If a
battery remains attached to the charger after complete
charging the charger automatically switches to
maintenance charging. The battery is also charged with
maintenance charging if another mode is selected.
Mode 1 (6 V to max. 14 Ah batteries)
Set this mode to charge 6 V lead acid batteries with a capacity
under 14 Ah.
• Press the MODE button several times to select Mode 1.
The LED display
lights up.
• If you then do not set another mode the electronics
automatically start the charging process with a charging
current of around 0.8 A. The LED
lights up throughout
13