1. Introduction
The USC423A GSM Alarm Panel is a control panel that is compatible with other
868MHz security devices from Everspring, such as wire free PIR Detectors, Remote
Controls and RFID tags.
Note: Due to frequency issues within the design of the USC423A GSM Alarm Control
panel. The USC423A GSM Alarm Control Panel is not compatible with Three Network
SIM Cards used in the UK.
2. Product overview
A. Touch keypad
B. Microphone
C. Siren
USC423A 868MHz GSM Alarm System
868MHz GSM Alarm System
D. RFID sensor area
E. GSM status led

User Manual

F. Speaker
When battery cover is removed:
I. SIM card slot
K. DC-jack
1
G. Battery cover
H. Wall mounting bracket
J. Battery connector
L. Factory reset

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USC423A and is the answer not in the manual?

Questions and answers

Summary of Contents for LuxHome USC423A

  • Page 1: User Manual

    868MHz GSM Alarm System User Manual 1. Introduction The USC423A GSM Alarm Panel is a control panel that is compatible with other 868MHz security devices from Everspring, such as wire free PIR Detectors, Remote Controls and RFID tags. Note: Due to frequency issues within the design of the USC423A GSM Alarm Control panel.
  • Page 2: Sim Card Installation

    2. Insert a SIM card into the slot and connect the 9V power adapter. 3. Wait until the GSM status led blinks slowly (once every 3 seconds) indicating the SIM card is ready for use. USC423A 868MHz GSM Alarm System...
  • Page 3: Mounting The Alarm Panel

    3. Power on the panel and test to make sure the GSM has good signal. Please see LED & Keys keyfob 1- 9, or RFID tags 1-4 Test Mode Point 4. Number 0 On: Indicator for Detector zone > 9 or RFID tags > 4. LED & Key USC423A 868MHz GSM Alarm System...
  • Page 4 The Host Phone Number will automatically appear as the first number in the list of when Fully Armed / Partial Armed / Disarmed. Alarm Voicecall number, Alarm SMS Phone number and Speed Dial No. in Appendix B USC423A 868MHz GSM Alarm System...
  • Page 5 Remote keyfobs, Wireless Keypad, and SMS/App can be used to operate Arm / Pressing the PARTARM Key will check all doors and windows under Partial Arm Partial Arm / Disarm the system. and display LED opened doors or windows for 3 seconds. USC423A 868MHz GSM Alarm System...
  • Page 6 Phone control mode When called, the user may press the “” key on the phone. This will stop the siren and the panel will enter phone control mode to wait for next input key: USC423A 868MHz GSM Alarm System...
  • Page 7: Telephone Functions

    When the Detector is triggered the alarm will sound immediately 1. Power on the device by inserting its batteries. without any preset delay. 2. On the alarm panel, enter the PIN + DISARM Key to disarm the system. USC423A 868MHz GSM Alarm System...
  • Page 8: Hot Key Functions

    Follow the steps in Appendix A to remove a Detector or other devices from the alarm panel’s binding memory. For Detectors/Remote Control/RFID tags numbered 1-9, you can select directly from the keypad. Note: The alarm panel must be in Disarm mode. USC423A 868MHz GSM Alarm System...
  • Page 9: Basic Troubleshooting

    868MHz GSM Alarm System 14. Troubleshooting 13-2 Restore to factory settings The user may choose to perform a factory reset to return the USC423A to factory 13-1 Basic Troubleshooting default settings. Please note that all configurations (including recorded alarm 13-1-1 The alarm panel cannot register with a GSM host (GSM Net LED flashes messages, contact lists and linked Detectors/Devices) will be deleted.
  • Page 10 Please DO NOT dispose of packaging as unsorted waste, use the recycling facilities provided by your local authorities. Manufacturer: Everspring Industry Company Limited 3F,No. 50, Sec 1 Zhonghua Road Tucheng District New Taipei City 23666 Taiwan TEL: +886222606868 FAX: +886222601313 USC423A 868MHz GSM Alarm System...
  • Page 11: Appendix A: Usc423A Keypad Operation Table

    USC423A 868MHz GSM Alarm System Appendix A: USC423A Keypad Operation Table Enter PIN code + 05 + 1 + Turn On Anti-Jamming Function Enter Key Explanation Enter PIN code + 05+ 2 + Detection Turn Off (Default) Exit Delay: Arm Key LED flashes and beeps...
  • Page 12 Delete all RFID tags after 10 Add wireless Same procedure for Remote keyfob, RFID Tag Enter PIN code + 15 + keypad and Keypad Enter PIN code + 20 + 4 Delete Wireless Delete wireless keypad keypad USC423A 868MHz GSM Alarm System...
  • Page 13: Appendix B: Sms Commands

    Entry & Exit Delay Time: xx Seconds 3. 022655XXXX Display (5 sets) Edit->Send back Siren Volume: Mute/Low/High 4. 0021626572XXXX Siren Ringing Time: xx Minutes 5. 08532XXXX (Note 2) Zone1 Name: Zone 1 Name (Note5) Zone1 USC423A 868MHz GSM Alarm System...
  • Page 14 Entry Delay & Set Delay Time Successfully (0-240 sec.): SMS Forward-> alarm panel model number and its software version. Exit Delay Time Edit->Send back (Note 5) Siren Volume (0 Mute, 1 Low, 2 High): 2 Siren Volume USC423A 868MHz GSM Alarm System...
  • Page 15: Appendix C: Sms Alerts

    Send "Zone name” battery is low Zone Low Battery For Other Zones: Send "Zone xx” battery is low Console Tamper Console tamper is triggered Keypad Tamper Keypad tamper is triggered Panic initiated Emergency help notify from Alarm panel USC423A 868MHz GSM Alarm System...

Table of Contents