■ Setting Function List
Dis-
Setting Function
Symbol
Setting Description
play
<DefaultValue>
(1)
Counter
:Whenselected,thecounterfunction
ON/OFFSetting
isavailable.
:Whenselected,itisusedasa
normaldriver.
ThedisplayisalsoOFF.
(2)
Count
Thescrewfasteningcountvalueisset.
SettingRange:1to99
(3)
CountTimer
Thisfunctionisusedtopreventthecount
fordoubletighteningoperationssuchas
checkfasteningorretightening.
Settheoperationtimewhilethecheck
fasteningisperformedforthetightenedscrew.
SettingRange:0.00to0.99seconds
Note: Whenthescrewtighteningoperation
isperformedduringsettingand
thejudgmentresultisnormal,the
buzzersoundsonce.
(4)
Work Reset Timer
Thebuzzersoundtimeperiodafterthe
workiscompletedisset.
SettingRange:0.0to3.9seconds
Note:Setitbasedonthereversecount
timersetvalue.
(5)
ReverseCount
Thetimeperioduntilthereversecount
Timer
isperformedisset.Settheworkreset
timeroperationtimebasedonthetime
perioduptowhenthereversecountis
performed.
SettingRange:0.1to1.0seconds
Note:Itisavailablewhenthe"Reverse
CountEnable"hasbeensetinthe
systemsetting.
(6)
SystemSetting
EachBuzzerorReverseCountEnable/
Disableissetup.
Thesettingisperformedwitha
combinationofthetensdigitandsingle
unitdigit.
TensDigit
0:BuzzerEnable/ReverseCountEnable
1:BuzzerEnable/ReverseCountDisable
2:BuzzerDisable/ReverseCountEnable
3:BuzzerDisable/ReverseCountDisable
UnitsDigit
2:TorqueUpBuzzerDisable
3:TorqueUpBuzzerEnable
(7)
OverTime/
ThissetswhetherornottheOverTime/
ShortTime
ShortTimeerrorisdetected.
0:Whenselected,neitherOverTimeor
ShortTimeErrorisdetected.
1:Whenselected,onlytheShortTime
Errorisdetected.
2:Whenselected,onlytheOverTime
Errorisdetected.
3:Whenselected,thebothOverTime/
ShortTimeErroraredetected.
Dis-
Setting Function
Symbol
Setting Description
play
<DefaultValue>
(8)
Accumulated
Theaccumulatedcountofthescrew
Counter
fasteningoperationisdisplayed.
Fortheaccumulatedcount,allthetorque-
upoperationsarecountedregardlessof
whetherthecounterisON/OFF.
Display
■ Operation
ChangingtotheSettingMode
PresstheF1Buttonformorethan2secondsinthenormalmode.
"P"willbedisplayedinthefunctiondisplaysectionandthemodewillbe
changedtothesettingmode.
SettingMode
EachpressingoftheF1Buttoninthesettingmodechangesthesetting
item.Referto"SettingFunctionList"forthesettingfunctiondetails.
(Count)
(Count Timer)
(Work Reset Timer)
(Reverse Count Timer)
(System Setting)
(Over Time/Short Time)
(Accumulated Counter)
ChangingtotheNormalMode
PresstheF1Buttonformorethan2secondsinthesettingmode.
Themodewillbechangedtothenormalmodeandthevaluesetfor
thecountwillbedisplayed.
Howtoreadthedisplay
UnitsDigit:Numberedinmultiples
of100,000shots
TensDigit:Numberedinmillions
ofshots
CounterON/OFFSetting
EachpressingoftheF3ButtontogglesONandOFF.
(Note:F2Buttonisnottobeused.)
ValueSettingforEachFunction
1.EachpressingoftheF2Buttoninthesettingmode
changesthefigurepositionforsetting.
2. E achpressingoftheF3Buttonincreasesthevalueoneby
one.
Note:Thesettingprocedureisthesameforallthesettings

exceptforthe"CounterON/OFFSetting".
Referto" ■ SettingFunctionList"forthesettingrange.