Software
None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated carrier), 0 (sends
PARAMETERS
a 2 kHz modulated carrier) or 5 (sends a mixed 1 + 2 kHz modulated carrier).
Nothing.
RETURNS
The system stops, and exits the command only when a key is pressed. This com-
REMARKS
mand returns no message.
No.
REMOTE
EXAMPLE
TX
193 TX 0
#
TX 1
193 TX 0
#
TX 5
193 TX 0
#
B
Sends a broadcast frame.
DESCRIPTION
None.
PARAMETERS
A data block.
RETURNS
After the device sends the broadcast frame, it will listen for answers. All valid an-
REMARKS
swers will be listed with their IDs.
No.
REMOTE
EXAMPLE
B
193 B 0
#234 BA 0
#7851 BA 0
4.3.5.
Returned errors list
Following are error messages you might get.
Command line interpreter
56
• 1 — nonexistent command
• 2 — command line buffer overflow (input line too long)
• 3 — internal error
• 4 — reserved
• 5 — missing or false parameters in command